DM RAID: Fix comparison of index and quantity for "rebuild" parameter
The "rebuild" parameter takes an index argument that starts counting from
zero. The conditional used to validate the index was using '>' rather than
'>=', leaving the door open for an index value that would be 1 too large.
Reported-by: Neil Brown <redacted>
Signed-off-by: Jonathan Brassow <redacted>
Index: linux-upstream/drivers/md/dm-raid.c
===================================================================
--- linux-upstream.orig/drivers/md/dm-raid.c
+++ linux-upstream/drivers/md/dm-raid.c
@@ -539,7 +539,7 @@ static int parse_raid_params(struct raid
/* Parameters that take a numeric value are checked here */
if (!strcasecmp(key, "rebuild")) {
- if (value > rs->md.raid_disks) {
+ if (value >= rs->md.raid_disks) {
rs->ti->error = "Invalid rebuild index given";
return -EINVAL;
}