When RAID-4,5,6 degraded and met read-error, it will eject the rdev.And then
the RAID will fail and lost data.Because the function of set-badsector,when
this occur,it will set-badsector,not ejecting the rdev.
When RAID-4,5,6 met read-error, it will re-write if RAID was not degrade.But if
re-write error,it will eject the rdev and RAID will degrade and it will take too
long time for recoverying.So I add judgement for controling how may re-write-error
can eject the rdev.
I do those for flexible controling the read-error for different situation.
majianpeng (2):
md/raid456: When readed error and raid was degraded,it try to
set badsector, not ejecting the rdev.
md/raid456:Add interface for contorling eject rdev when re-write
failed.
drivers/md/md.c | 35 +++++++++++++++++++++++++++++++++++
drivers/md/md.h | 2 ++
drivers/md/raid5.c | 28 +++++++++++++++++++---------
3 files changed, 56 insertions(+), 9 deletions(-)
--
1.7.5.4
--------------
majianpeng
2012-05-26