Thread (4 messages) 4 messages, 2 authors, 2012-05-03

Re: Monitoring for failed drives

From: Jan Ceuleers <hidden>
Date: 2012-04-25 16:18:05

Brian Candler wrote:
The problem is, how to detect and report this? At the md RAID level,
`cat /proc/mdstat` and `mdadm --detail` show nothing amiss.

     # cat /proc/mdstat
     Personalities : [linear] [multipath] [raid0] [raid1] [raid6] [raid5] [raid4] [raid10]
     md127 : active raid0 sdk[8] sdf[4] sdb[0] sdj[9] sdc[1] sde[2] sdd[3] sdi[6] sdg[5] sdh[7] sdv[20] sdw[21] sdl[11] sdu[19] sdt[18] sdn[13] sds[17] sdq[14] sdm[10] sdx[22] sdr[16] sdo[12] sdp[15] sdy[23]
           70326362112 blocks super 1.2 512k chunks
Brian,

I know that you know this, but this is a RAID0 which does not have any 
redundancy. What would you expect md to do? It cannot kick the drive 
from the array since this would bring the entire array down.

Unlike with other RAID levels it is practicable to kick failed drives 
from the array because you can reconstruct their contents from the 
parity information.

Jan