Thread (7 messages) 7 messages, 3 authors, 2011-10-18

Re: [PATCH] MD: Allow restarting an interrupted incremental recovery.

From: NeilBrown <hidden>
Date: 2011-10-18 23:00:08

On Tue, 18 Oct 2011 13:15:27 -0700 (PDT) Andrei Warkentin
[off-list ref] wrote:
----- Original Message -----
quoted
From: "Andrei Warkentin" <redacted>
To: "NeilBrown" <redacted>
Cc: linux-raid@vger.kernel.org, "Andrei Warkentin" <redacted>
Sent: Tuesday, October 18, 2011 4:06:05 PM
Subject: Re: [PATCH] MD: Allow restarting an interrupted incremental recovery.

Hi Neil,

----- Original Message -----
quoted
From: "Andrei Warkentin" <redacted>
To: "NeilBrown" <redacted>
Cc: linux-raid@vger.kernel.org, "Andrei Warkentin"
[off-list ref]
Sent: Tuesday, October 18, 2011 1:07:24 PM
Subject: Re: [PATCH] MD: Allow restarting an interrupted
incremental recovery.
quoted
Also I realised that clearing saved_raid_disk when an array is
not
degraded
is no longer enough.  We also need to clear it when the device
becomes
In_sync.
Consider a 3-drive RAID1 with two drives missing.  You add back
one
of them
and when it is recovered it needs saved_raid_disk cleared so that
the
superblock gets written out.

So below is what I applied.
Wouldn't all drives being In_sync imply the array is not degraded -
i.e. can the
check for a degraded array be omitted then, at all? I.e. if after
the
resync the
In_sync bit is set - drop saved_raid_role.
Come to think of it - checking for !mddev->degraded might not be a
good idea at all. After all, you
could imagine a situation where in a RAID1 array with A and B, A is
recovered from B and then B goes away before
the SBs are flushed due to resync finishing - you would still want
A's SB to be flushed, even if array is degraded.

Otherwise you'll end up with another incremental rebuilding A, and
lost/inconsistent data after array became degraded (since it was
going to A, but we never wrote out its SB, since array is degraded).
Errr, I confused myself. This is exactly why you added the check for In_sync.
OTOH, isn't the mddev->degraded now superflous - i.e. if all disks are In_sync,
there is no need to check for degraded, right?

A
Maybe.
However once we clear mddev->degraded we can start clearing bits in the
bitmap, so any saved_raid_disk information is definitely invalid and should
be removed.
You would expect that there won't be any, and you would probably be right.
But it feels safer keeping the check there.  It is probably superfluous, but
sometimes a little paranoia can be a good thing.

Thanks,
NeilBrown