On Mon, Aug 15, 2011 at 7:55 PM, NeilBrown [off-list ref] wrote:
Yes, add another one later would be difficult. But if you know up-front that
you will want three off-site devices it is easy.
You could
mdadm -C /dev/md0 -l1 -n2 -b internal /dev/A missing
mdadm -C /dev/md1 -l1 -n2 -b internal /dev/md0 missing
mdadm -C /dev/md2 -l1 -n2 -b internal /dev/md1 missing
mdadm -C /dev/md3 -l1 -n2 -b internal /dev/md2 missing
mkfs /dev/md3 ; mount ..
So you now have 4 "missing" devices.
Alright, so I tried that on my project, being a low-end device is
resulted in about 30-40% performance lost with 8 MDs (planning in
advance), I tried disabling all bitmap to see if it helps and I get
minimal performance gain. Is there anything I should tune in this
case?
--
To unsubscribe from this list: send the line "unsubscribe linux-raid" in
the body of a message to majordomo@vger.kernel.org
More majordomo info at http://vger.kernel.org/majordomo-info.html