Thread (13 messages) 13 messages, 7 authors, 2011-07-25

Re: mdadm striped parity RAID with Advanced Format drives

From: Michael Tokarev <hidden>
Date: 2011-07-25 18:57:18

25.07.2011 12:41, Nikolay Kichukov wrote:
I can confirm this has happened to me once. The drive went just a bit smaller than it was originally. Unfortunately I
have no evidence of this at this stage. It was real strange. Whatever I tried did not bring the same size back. It kept
being reported as a few sectors less.
It's possible to get smaller size at one point, by enabling HPA area
in a drive.  I think all modern (desktop) drives support this feature.

/mjt
Cheers,
-Nik

On 07/23/2011 09:03 PM, maurice wrote:
quoted
On 7/23/2011 9:58 AM, Mikael Abrahamsson wrote:
quoted
..
I'd like to see text that indicates this. I agree with the original poster that this just doesn't happen.
I no longer have the details at hand, as I have fixed it, and it was about 8 months ago last time I saw it.