Re: Do I understand my RAID6 correctly?
From: Stefan G. Weichinger <hidden>
Date: 2011-04-12 10:42:26
Am 12.04.2011 11:23, schrieb Yann Ormanns:
You now have 9 devices in this Array (750GB*8 = 6 TB, 6 TB - (2*750GB) = 4.5 TB). One of them is the failed spare disk. That means, that this array can "lose" two disks without losing data, as you already wrote.
Yep, fine.
Of course you can re-use /dev/sdk as a spare disk, but before, you should check, why it failed (SMART data for example).
I already exported the controller-logs and will look through for SMART info. Unfortunately the controller does not allow the use of smartmontools, I can only use the specific ICP Storage Manager.
You should also have a look at the used drive models. E.g. if this array uses 9x model XYZ from manucaturer ABC, perhaps more drives will fail in the next time.
uuuh
If the array uses mixed models, it should not be THAT urgent - but that depends on the importance of the data... I've read several times of people losing their RAID6, because they did not mix the hard drive models. Then, a manufacturing fault have very bad consequences.
Scary. Yes, the server uses the same model for all 9 devices. From your domain I see that you seem to be located in germany, so you might know the manufacturer of the server: transtec. I already opened a support ticket there, we still have a valid support contract. Last time they sent a new drive, we'll see. Thanks, Stefan