On Thu Jul 08, 2010 at 12:26:27PM +0200, Mikael Abrahamsson wrote:
It seems the driver doesn't implement that, I can see it for the
ICH10R-controller, but not for the SiL-based one this drive is on:
[ 1.289345] ahci 0000:08:00.0: setting latency timer to 64
[ 1.289436] scsi12 : ahci
[ 1.289501] scsi13 : ahci
[ 1.289542] ata13: SATA max UDMA/133 abar m2048@0xfbeff000 port 0xfbeff100 irq 40
[ 1.289546] ata14: SATA max UDMA/133 irq_stat 0x80400040 irq 40, connection status changed
[ 1.638532] ata13: SATA link down (SStatus 0 SControl 370)
[ 2.218075] ata14: SATA link up 3.0 Gbps (SStatus 123 SControl 370)
[ 2.223478] ata14.00: ATA-8: WDC WD20EADS-00R6B0, 01.00A01, max UDMA/133
[ 2.223483] ata14.00: 3907029168 sectors, multi 0: LBA48 NCQ (depth 31/32), AA
[ 2.228491] ata14.00: configured for UDMA/133
It would look like ata14 is the equivalent of scsi13 then - lsscsi or
"cat /proc/scsi" should show you the drives connected on controller 13
(or look in /sys/class/scsi_disk/13*/device/block).
Cheers,
Robin
--
___
( ' } | Robin Hill [off-list ref] |
/ / ) | Little Jim says .... |
// !! | "He fallen in de water !!" |