Re: possible bus loading problem during resync
From: Asdo <hidden>
Date: 2010-03-12 11:00:32
quoted
If that is true, how does that happen, the driver is hung? But anyway, how can such things happen when there is more than one CPU-core?A drive produces an error, the whole controler hangs and resets all ports, all drives have to finish being reset before any IO can continue. Hapens easily enough.
Ok but this is a multi-core CPU and he said Putty and WinSCP were hung. Ok for WinSCP... but Putty? Timothy is Putty hung on array check even on NCQ disabled? What is the resync speed? If it is very high it could be a CPU starvation but it's strange with only 2 drives. If it is very low I am not sure. Are disks write caches enabled? I am not able to spot any problem from your iostat or dmesg. Note: yes the iostat -x 1 was supposed to be captured during resync. Trigger a resync manually for the test. You can start it with echo check and stop it with echo idle > /sys/block/mdX/md/sync_action