Re: RAID-5 degraded mode question

From: Goswin von Brederlow <hidden>
Date: 2009-12-22 13:37:48

Michael Evans [off-list ref] writes:
On Mon, Dec 21, 2009 at 4:41 AM, Goswin von Brederlow [off-list ref] wrote:
quoted
"Tirumala Reddy Marri" [off-list ref] writes:
quoted
Thanks for the response.
quoted
quoted
 Also as soon as disk failed md drivers marks that drive as faulty
and
quoted
quoted
continue operation in degraded mode right ? Is there a way to get out
quoted
quoted
the degraded mode without adding spare drive. Assuming we have 5 disk
quoted
quoted
system with one failed drive.
I'm not sure what you want to happen here.  The only way to get out of
degraded mode is to replace the drive in the >array (if it's not
actually faulty then you can add it back, otherwise you need to add a
new drive).
quoted
What were you thinking might happen otherwise?

I was thinking we can recover from this using re-sync or resize .After
Theoretically you could shrink the array by one disk and then use that
spare disk to resync the parity. But that is a lengthy process with a
lot higher failure chance than resyncing to a new disk. Note that you
also need to shrink the filesystem on the raid first adding even more
stress and failure chance. So I really wouldn't recommend that.
quoted
running IO to degraded (RAID-5) /dev/md0, I am seeing an issue where
e2fsck reports inconsistent file system and corrects it. I am trying to
debug  to see if the issue is because of data not being written or
reading wrong data in degraded mode.

I guess problem happening during the write. Reason is , after ran e2fsck
I don't see inconsistency any more.

Regards,
Marri
A degraded raid5 might get corrupted if your system crashes. If you
are writing to one of the remaining disks then it also needs to update
the parity block simultaneously. If it crashed between writing the
data and the parity then the data block on the failed drive will
appear changed. I'm not sure though if the raid will even assemble on
its own in such a case though. It might just complain about not having
enough in-sync disks.

Apart from that there should never be any corruption unless one of
your disks returns bad data on read.

MfG
       Goswin

PS: This is not a bug in linux raid but a fundamental limitation of
raid.
--
To unsubscribe from this list: send the line "unsubscribe linux-raid" in
the body of a message to majordomo@vger.kernel.org
More majordomo info at  http://vger.kernel.org/majordomo-info.html
You're forgetting the every horrid possibility of failed/corrupted
hardware.  I've had IO cards go bad due to a prior bug that let an
experimental 'debugging' option in the kernel write to random memory
locations in the rare case of an unusual error.  Not just the
occasional rare chance of a buffer being corrupted, but the actual
hardware going bad.  One of the cards could not even be recovered by
an attempt at software-flashing the firmware (it must have been too
far gone for the utility to recognize, and replacing it was the least
expensive route remaining).

However in general I've seen hardware that's actually failing will
tend to do so with enough grace to either outright refuse to operate,
or operate with obvious and persistent symptoms.
And how is that relevant to the raid-5 being degraded? If the hardware
goes bad you just get errors no matter what.

MfG
        Goswin
--
To unsubscribe from this list: send the line "unsubscribe linux-raid" in