RE: Spurious HD convictions
From: lrhorer@satx.rr.com <hidden>
Date: 2009-12-13 03:44:53
Hmm. I don't see how it could be either the PS or the PMs, since the drives were moved to a new enclosure when the problem started happening, yet the problem persists. The new chassis has all new PMs and of course a new PS, and the problem is happening across multiple PMs. In addition, if NCQ is the problem, why has it just started happening? This system has been up and running for the better part of a year. Regardless, I have disabled NCQ by executing `echo 1 > /sys/block/sd[a-g]/device/queue_depth`, and I am attempting a repair action again. We'll see how it goes.
Hi Leslie, According to some of the links here: http://www.google.com/search?hl=en&q=failed+to+read+SCR+1+(Emask%3D0x40) It seem to be either the Power Supply Unit (PSU) or the Port Multiplier (PM). A quick workaround seem to be disabling NCQ on all affected devices. On Sun, Dec 13, 2009 at 5:02 AM, lrhorer@satx.rr.com [off-list ref] wrote:quoted
What's happening here? Suddenly, my backup server is sufferingapparentlyquoted
spurious hard drive convictions. The server is running RAID5 on 7 disks under md. It has been running well for months, but suddenly it hasstartedquoted
kicking drives from the array when under moderately heavy read or write loads. The thing is, it isn't convicting any particular driverepeatedly,quoted
and the drives are not showing any errors under SMART. This is a PMsystem,quoted
and I have tried changing the drive adapters, changing the PMs, changing cables, moving the drives around, and moving them out of the CPUenclosure toquoted
a new external chassis. The convictions are not occurring on any one channel, over any one particular PM, or over any particular cable.Sincequoted
this started happening, I have been unable to get all the way through a resync before the array dumps at least one of the drives. Here is asamplequoted
from the kernel log during one of the convictions: