Re: Raid 5 - not clean and then a failure.
From: Jon Hardcastle <hidden>
Date: 2009-08-25 08:40:31
--- On Tue, 25/8/09, Robin Hill <robin@robinhill.me.uk> wrote:
From: Robin Hill <redacted> Subject: Re: Raid 5 - not clean and then a failure. To: linux-raid@vger.kernel.org Date: Tuesday, 25 August, 2009, 9:16 AM On Tue Aug 25, 2009 at 12:54:49AM -0700, Jon Hardcastle wrote:quoted
Guys, I have been having some problems with my arrays that Ithink i havequoted
nailed down to a pci controller (well I say that - itis always thequoted
drives connected to *a* controller but I have tried2!) anyway thequoted
latest saga is i was trying some new kernel optionslast night - whichquoted
didn't work.Did they have the same chipset? I had problems with PCI controllers on one of my systems, which turned out to be some sort of conflict between the onboard chipset and the chipset on the controllers. I found a PCI card with a different chipset and have had no issues since.
They are/were cheapy little via ones from 'aria' I got a new one and installed it along side a week ago 1 drive on it to 'test', when my array came to do a scrub a week later I got a whole host of issues. I am not sure what the cause was but now either of the controllers seem work reliably. I have a pci express controller but my kernel doesnt (yet!) support pci express. Do you know of you can get sata 3 on pci? or is it too slow?
quoted
But when i booted up again this morning it said one ofthe drives wasquoted
in an inconsistent state (not sure of the *exact*error message). Iquoted
then kicked off an add of the drive and it startedsyncing. It gotquoted
about 5% in and then the second drive in on thatcontroller complainedquoted
and the array failed. Is there any hope for my data? If i get a goodcontroller in therequoted
will the resync continue? can I try and tell it toassume the drivesquoted
are good (which they ought to be)?There's definitely hope. You can assemble the array (using the good drives and the last drive to fail) using the --force option, then re-add (and sync) the other drive (I'd recommend doing a fsck on the filesystem as well). I've just had to do a similar thing myself after two drives failed (overheated after a fan failure). Cheers, Robin --
Thank you, Thank you, Thank you. I probably wont look at this for a few days now - i find when sitting down without enough time to really see it through is when I get problems! and I am abit busy bee atm!
-----------------------
N: Jon Hardcastle
E: Jon@eHardcastle.com
'Do not worry about tomorrow, for tomorrow will bring worries of its own.'
-----------------------
--