Re: Raid and badblocks
From: Sujit Karataparambil <hidden>
Date: 2009-05-30 14:21:28
quoted
We have a linux RAID 5 md setup with 10 disks controlled using a 3ware 9650se card. Here is /proc/mdstat:
quoted
Personalities : [raid6] [raid5] [raid4] md0 : active raid5 sdb1[0] sdk1[9] sdj1[8] sdi1[7] sdh1[6] sdg1[5] sdf1[4] sde1[3] sdd1[2] sdc1[1]
>> 8788959360 blocks level 5, 32k chunk, algorithm 2 [10/10] [UUUUUUUUUU] Above the Raid Configuration. (Cut and Paste and other info)
3w-9xxx: scsi4: ERROR: (0x03:0x0202): Drive ECC error:port=8. sd 4:0:8:0: [sdj] Unhandled sense code sd 4:0:8:0: [sdj] Result: hostbyte=DID_OK driverbyte=DRIVER_SENSE,SUGGEST_OK sd 4:0:8:0: [sdj] Sense Key : Medium Error [current] sd 4:0:8:0: [sdj] Add. Sense: Unrecovered read error
3ware 9650se card/check whether the drive on sdj is plugged in properly. since the error is sd 4:0:8:0: [sdj] Unhandled sense code. Probably an jumper. But why does the error come up as read error. Is the read error given priority/ precedence over write error in the hardware?
end_request: I/O error, dev sdj, sector 1953102848 3w-9xxx: scsi4: ERROR: (0x03:0x0202): Drive ECC error:port=8. sd 4:0:8:0: [sdj] Unhandled sense code sd 4:0:8:0: [sdj] Result: hostbyte=DID_OK driverbyte=DRIVER_SENSE,SUGGEST_OK sd 4:0:8:0: [sdj] Sense Key : Medium Error [current] sd 4:0:8:0: [sdj] Add. Sense: Unrecovered read error
3ware 9650se card. Same here.
end_request: I/O error, dev sdj, sector 1953102856 Buffer I/O error on device sdj, logical block 244137857 Buffer I/O error on device sdj, logical block 244137858 Buffer I/O error on device sdj, logical block 244137859 Buffer I/O error on device sdj, logical block 244137860 Buffer I/O error on device sdj, logical block 244137861 Buffer I/O error on device sdj, logical block 244137862 Buffer I/O error on device sdj, logical block 244137863 Buffer I/O error on device sdj, logical block 244137864 Buffer I/O error on device sdj, logical block 244137865 Buffer I/O error on device sdj, logical block 244137866
This is an read error as the disk is being added to the raid. Here the sector and logical block is being looked for.
3w-9xxx: scsi4: ERROR: (0x03:0x0202): Drive ECC error:port=8. sd 4:0:8:0: [sdj] Unhandled sense code sd 4:0:8:0: [sdj] Result: hostbyte=DID_OK driverbyte=DRIVER_SENSE,SUGGEST_OK sd 4:0:8:0: [sdj] Sense Key : Medium Error [current] sd 4:0:8:0: [sdj] Add. Sense: Unrecovered read error end_request: I/O error, dev sdj, sector 1953103080 3w-9xxx: scsi4: ERROR: (0x03:0x0202): Drive ECC error:port=8. sd 4:0:8:0: [sdj] Unhandled sense code sd 4:0:8:0: [sdj] Result: hostbyte=DID_OK driverbyte=DRIVER_SENSE,SUGGEST_OK sd 4:0:8:0: [sdj] Sense Key : Medium Error [current] sd 4:0:8:0: [sdj] Add. Sense: Unrecovered read error end_request: I/O error, dev sdj, sector 1953103080 3w-9xxx: scsi4: ERROR: (0x03:0x0202): Drive ECC error:port=8. sd 4:0:8:0: [sdj] Unhandled sense code sd 4:0:8:0: [sdj] Result: hostbyte=DID_OK driverbyte=DRIVER_SENSE,SUGGEST_OK sd 4:0:8:0: [sdj] Sense Key : Medium Error [current] sd 4:0:8:0: [sdj] Add. Sense: Unrecovered read error
3ware 9650se card. Same Here.
end_request: I/O error, dev sdj, sector 1953103080 __ratelimit: 24 callbacks suppressed Buffer I/O error on device sdj, logical block 244137885
Sector and block info.
3w-9xxx: scsi4: ERROR: (0x03:0x0202): Drive ECC error:port=8. sd 4:0:8:0: [sdj] Unhandled sense code sd 4:0:8:0: [sdj] Result: hostbyte=DID_OK driverbyte=DRIVER_SENSE,SUGGEST_OK sd 4:0:8:0: [sdj] Sense Key : Medium Error [current] sd 4:0:8:0: [sdj] Add. Sense: Unrecovered read error
Same here.
end_request: I/O error, dev sdj, sector 1953103080 Buffer I/O error on device sdj, logical block 244137885 md: requested-resync of RAID array md0 md: minimum _guaranteed_ speed: 1000 KB/sec/disk. md: using maximum available idle IO bandwidth (but not more than 200000 KB/sec) for requested-resync. md: using 128k window, over a total of 976551040 blocks. md: md0: requested-resync done.
is it printing out information regarding minimum/optimal speed/IO bandwidth due to the an failed/partially failed device.
-- Jeremy Sanders [off-list ref] http://www-xray.ast.cam.ac.uk/~jss/ -- To unsubscribe from this list: send the line "unsubscribe linux-raid" in the body of a message to majordomo@vger.kernel.org More majordomo info at http://vger.kernel.org/majordomo-info.html
-- -- Sujit K M