Re: Requesting replace mode for changing a disk
From: Goswin von Brederlow <hidden>
Date: 2009-05-13 03:27:28
"Leslie Rhorer" [off-list ref] writes:
quoted
This is one of many things proposed occasionally here, no real objection, sometimes loud support, but no one actually *does* the code.At the risk of being a metoo, I would really love this feature.quoted
You have described the problem exactly, and the solution is still to do it manually. But you don't need to fail the drive long term, if you can stop the array for a few moments. You stop the array, remove the suspect drive,Um, how, exactly? That is to say, after stopping the array, how does one remove the drive? From the next step in your suggestion, it doesn't seem tome you are talking about physically removing the drive, so how does one remove a drive from a stopped array for this purpose? I didn't think that either mdadm -r <drive> <array> or mdadm -f <drive> <array> could be used on a stopped array. Am I mistaken?quoted
create a raid1 of the suspect drive marked write-mostly and the new spare,But doesn't creating the array with the drive wipe the contents? If so, it doesn't seem to me this provides much redundancy.quoted
then add the raid1 in place of the suspect drive.Before starting the array? If so, how? Or should one do an assemble including the newly minted RAID1? I thought mdadm would take the newly added drive to be blank, even if it isn't.quoted
For any chunks present on the new drive the reads will go there, reducingHuh? Are you saying any read which finds one chunk missing will automatically write back the missing data (doing a spot rebuild), or something else?quoted
access, while data is copied from the old to the new in resync, andSee my query above. It seems to me you are saying the RAID1 can be created without wiping the drive.quoted
writes still go to the old suspect drive so if the new drive fails you are no worse off.I think I would expect the old drive to be more likely to fail than the new.quoted
When the raid1 is clean you stop the main array and back the suspect drive out.OK, basically the same question. How does one disassemble the RAID1 array without wiping the data on the new drive?
I think he ment this:
mdadm --stop /dev/md0
mdadm --build /dev/md9 --chunk=64k --level=1 --raid-devices=2 /dev/suspect /dev/new
mdadm --assemble /dev/md0 /dev/md9 /dev/other ...
MfG