Re: SLES, not large enough to join array
From: Neil Brown <hidden>
Date: 2008-08-01 05:16:03
On Thursday July 31, leituras@gmail.com wrote:
Hi. I have a setup with SLES 10 SP2 installed in 1 DELL PowerEdge 2950 attached to 5 DELL MD1000 SAS storages (5 TB each). I used mdadm to make a single RAID unit of my storages. I'm using RAID 5 to prevent data loss if one of the storages fail. I had a storage fail. I removed the faulty storage (mdadm /dev/md0 -r /dev/sdb1) and restarted the system to replace this storage with a good one. The new storage is an exact copy of the faulty one (including internal HD's). When I tried to add the new storage to my degraded array ( mdadm /dev/md0 -a /dev/sdX1), I get the following message: /dev/sdX: not large enough to join array. I used the same steps in another site (with the same storages, but with only 500 GB each) and it worked all right. Any suggestions?
Yes. Upgrade :-) This looks like the bug that was fixed in SLES10-SP2 by an update on May 9th this year. The relevant bugzilla is https://bugzilla.novell.com/show_bug.cgi?id=368704 There is a patch linked in there. If you cannot find an upgrade, you could just compile your own mdadm from the latest source. NeilBrown