Thread (6 messages) 6 messages, 3 authors, 2006-11-07

Re: RAID5 array showing as degraded after motherboard replacement

From: dean gaudet <hidden>
Date: 2006-11-06 08:29:52


On Mon, 6 Nov 2006, James Lee wrote:
Thanks for the reply Dean.  I looked through dmesg output from the
boot up, to check whether this was just an ordering issue during the
system start up (since both evms and mdadm attempt to activate the
array, which could cause things to go wrong...).

Looking through the dmesg output though, it looks like the 'missing'
disk is being detected before the array is assembled, but that the
disk is throwing up errors.  I've attached the full output of dmesg;
grepping it for "hde" gives the following:

[17179574.084000]     ide2: BM-DMA at 0xd400-0xd407, BIOS settings:
hde:DMA, hdf:DMA
[17179574.380000] hde: NetCell SyncRAID(TM) SR5000 JBOD, ATA DISK drive
[17179575.312000] hde: max request size: 512KiB
[17179575.312000] hde: 625134827 sectors (320069 MB), CHS=38912/255/63, (U)DMA
[17179575.312000] hde: set_geometry_intr: status=0x51 { DriveReady
SeekComplete Error }
[17179575.312000] hde: set_geometry_intr: error=0x04 { DriveStatusError }
[17179575.312000] hde: cache flushes supported
is it possible that the "NetCell SyncRAID" implementation is stealing some 
of the sectors (even though it's marked JBOD)?  anyhow it could be the 
disk is bad, but i'd still be tempted to see if the problem stays with the 
controller if you swap the disk with another in the array.

-dean