Re: Software RAID1 problems
From: Neil Brown <hidden>
Date: 2005-09-23 15:52:05
On Friday September 23, A.J.Dawson@Bradford.ac.uk wrote:
After a fairly long time without seeing the following message: "This is an automatically generated mail message from mdadm running on servername A DegradedArray event had been detected on md device /dev/md0. Faithfully yours, etc." It reared its head again today. I've checked dmesg and /var/log/messages and the only thing I've found so far is the following in dmesg: md: considering sda1 ... md: adding sda1 ... md: created md0 md: bind<sda1> md: running: <sda1> raid1: raid set md0 active with 1 out of 2 mirrors md1 works fine and md sets md1 active with 2 out of 2 mirrors. /dev/sdb2 is the device that appears to be causing the problem, so can anyone tell me what might be happening? Any ideas why it might not be included in the array at boot time? (I've tried Google but found no answers yet). Any help would be appreciated!
Looks a lot like sdb2 (sure it isn't sdb1?) isn't type 'FD'. NeilBrown