Re: number of global spares?
From: Dan Stromberg <hidden>
Date: 2005-08-27 05:50:51
On Sat, 2005-08-27 at 08:56 +1000, Neil Brown wrote:
On Friday August 26, strombrg@dcs.nac.uci.edu wrote:quoted
I've been working on a RAID setup with dual RAID controllers and three expansion boxes - 48 disks in all, including data, parity and global spares.If there are 48 drives, why do your drive-numbers go up to 59? Confusing but not important.
Agreed. The hardware likes to do that.
Presumably these are 360G drives (or there abouts) and you are hoping to use about 42 for data and the remaining 6 for redundancy.
Around 380G.
I feel this a bit tight but could be workable. If you were using Linux-soft-raid, I would probably suggest 3 16-drive raid6 arrays, possibly making 1 a 15 drive raid6 so there is one global spare. However I gather you are using hardware RAID - do the controllers support RAID6 ??
I'd feel better about RAID 6, but the hardware doesn't support it.
quoted
Please be sure to use a fixed-pitch font when viewing the tables found below. BTW, if people weren't so terrified of HTML, I could just make a nice HTML table for easy reading without silly font requirements...You mean some mail readers use variable-width-fonts to display text/plain? How broken!
Heh.
quoted
Does anyone have any comments on: 1) The sanity of these 10 disk RAID 5's?It depends on the drives. If you are using you-only-get-what-you-pay-for-IDE-drives, then I would say it is insane. If you are using you-pay-for-the-quality SCSI drives, then you should be fairly safe.
They're SATA's.
quoted
2) The degree of loss of reliability incurred by moving 3 disks from global spare to data?That depends a bit on your warranty arrangements on the drives. If it's next-day-replacement (Really, truly) then it is probably OK. If it is 'send us the bad drive and we'll see what we can do', then I would suggest thinking again.
This'll be the next thing I ask the vendor.
quoted
3) The degree of loss of reliability incurred by moving 2 disks from global spare to data?Should be safe enough. However I don't understand why you have 4 9+1 arrays, and 1 X+1 for varying X. Maybe 9+1 is the largest the controller will give you, so you have to go to 5 arrays. In that case, 4 8+1 arrays, 1 9+1 array, and 2 global spares would seem a more sensible arrangement.
I'm going to pitch this (or maybe 3 8+1's) to the owner of the equipment and the vendor. It was the vendor that suggested the 9+1's.