Re: Spares and partitioning huge disks
flat view
From: Michael Tokarev <hidden>
Date: 2005-01-09 17:59:51
Peter T. Breuer wrote:
Michael Tokarev [off-list ref] wrote:quoted
I think all modern drives support bad block remapping on both read and write. But think about it: if there's a read error, it means the drive CAN NOT read the "right" data for some reason (for some definition of "right" anyway) -- ie, the drive "knows" there's some problem with the data and it can'tI really don't want RAID to fault the disk offline in this case. I want RAID to read from the other disk(s) instead, and rewrite the data on the disk that gave the fail notice on that sector, and if that gives no error, then just carry on and be happy ...
There where some patches posted to this list some time ago that tries to do just that (or a discussion.. i don't remember). Yes, md code currently doesn't do such things, and fails a drive after the first error -- it's the simplest way to go ;) /mjt