Re: Stress testing system?
From: Robin Bowes <hidden>
Date: 2004-10-09 17:19:18
Guy wrote:
Once a drive fails, md will not re-sync it automatically. It will just sit there in a failed state. If you had a spare, then it would re-sync automatically. I am not 100% sure but I think...if you were to reboot, after the reboot md will resync. If you reboot before the re-sync is done, the re-sync will start over, at lease with my version.
I think that's what must have happened.
I replaced the power supply and brought the box back up. It then froze
on me, so I powered down again and investigated, bring the box up and
down a few times in the process. I then noticed the loose power
connection, fixed it, and brought the box back up. I reckon the array
must have been re-syncing from that point and it had nothing to do with
bonnie++.
Incidentally, I do have a spare drive:
[root@dude home]# mdadm --detail /dev/md5
/dev/md5:
Version : 00.90.01
Creation Time : Thu Jul 29 21:41:38 2004
Raid Level : raid5
Array Size : 974566400 (929.42 GiB 997.96 GB)
Device Size : 243641600 (232.35 GiB 249.49 GB)
Raid Devices : 5
Total Devices : 6
Preferred Minor : 5
Persistence : Superblock is persistent
Update Time : Sat Oct 9 18:18:54 2004
State : clean
Active Devices : 5
Working Devices : 6
Failed Devices : 0
Spare Devices : 1
Layout : left-symmetric
Chunk Size : 128K
UUID : a4bbcd09:5e178c5b:3bf8bd45:8c31d2a1
Events : 0.1410301
Number Major Minor RaidDevice State
0 8 2 0 active sync /dev/sda2
1 8 18 1 active sync /dev/sdb2
2 8 34 2 active sync /dev/sdc2
3 8 50 3 active sync /dev/sdd2
4 8 66 4 active sync /dev/sde2
5 8 82 - spare /dev/sdf2
Cheers,
R.
--