Re: Write and verify correct data to read-failed sectors before degrading array?
From: Neil Brown <hidden>
Date: 2004-09-17 00:39:55
On Thursday September 16, tim@buttersideup.com wrote:
Just thinking out loud here, but I wonder if the following change is possible or worth making to this code? For a failed read, where the block is then successfully read from another drive, then attempt to write the correct data for this block to the device with the read failure (to try to see if the drive firmware thinks this sector is still usable, and if not then maybe it will reallocate the failed sector). If this write succeeds, and can be verified, then don't mark the sector bad (maybe just complain with a printk).. This would get around a lot of mirror failures that I see in operation.. In the past, I've had mirrors go bad with individual failed sectors in different locations on both drives, the array is then unusable (and the database server is dead, in my experience) unless you manually try to knit it back together with dd.
Yes. Great idea. Just as good as every other time it gets suggested :-) Unfortunately no-one has presented any actual *code* yet, and I haven't found/made/allocated time to do it. http://neilb.web.cse.unsw.edu.au/SoftRaid/01084418693 NeilBrown