Thread (1 message) 1 message, 1 author, 2004-08-18

Re: Spare-group drive affinity with mdadm?

From: Neil Brown <hidden>
Date: 2004-08-18 02:27:36

On Wednesday August 11, blc@redhat.com wrote:
Hello,

I've just setup a raid 10 array (6 mirrors striped together) and have 
two extra drives available as hot spares.  The mirrors themselves are 
composed of two drives on separate scsi controllers to keep the SCSI bus 
from saturating.  The performance of this setup is just phenomenal, but 
the hot spares are not yet setup.

It appears that when using mdadm that one can use the spare-group 
feature to share a single hot-spare amongst multiple raid groups. 
AFAICT, this is done by placing the hot spare or spares in a single 
mirror, then designating it as part of the same spare group as a number 
of other mirrors using the same spare-group name.  For instance, if 
/dev/md0 has two spare drives, but /dev/md1 does not, I can do this to 
share the spares:

ARRAY /dev/md0 level=raid1 num-devices=2 
devices=/dev/sda1,/dev/sde1,/dev/sdc1,/dev/sdd1 spare-group=g1
ARRAY /dev/md1 level=raid1 num-devices=2 devices=/dev/sdb1,/dev/sdf1 
spare-group=g1
ARRAY /dev/md2 level=raid0 num-devices=2 devices=/dev/md0,/dev/md1

This is very handy, but performance-wise it's suboptimal.  When a drive 
fails the system might activate a spare that's on a different scsi chain 
than the drive that just failed, reducing overall redundancy and 
throughput.   It'd be nice if when a drive fails, a hot spare on the 
same chain would be preferred over a drive on a different chain.  Of 
course this is a pretty arbitrary distinction and something that would 
need configuration, but it doesn't seem like too much of a stretch over 
what mdadm can do already.  Maybe some sort of extended mdadm.conf 
syntax like:

AFFINITY /dev/sda,/dev/sdb spares=/dev/sdc
AFFINITY /dev/sde,/dev/sdf spares=/dev/sdd

(Assuming sda, sdb and sdc are on one chain and sde, sdf, and sdd are on 
another).

Is an enhancement like this feasible?
No, at least not in that form.
Device names (like "sda") are not stable.  If drive is added or
removed, lots of names can change.  So hard coding them in mdadm.conf
is a bad idea.

I think the best solution would be to allow mdadm to run an external
program which makes a selection.
It could be given an MD array and a list of possible spares, and it
should return the preferred on.

You would then want to write a program (script?) that implemented
whatever policy you wanted.
You policy seems to be "balance active drives across scsi busses",
which would require checking each array, and possibly looking at drive
stats to see which drives were actually being used.
This is certainly a reasonable policy, but someone else might want a
different one....

Does that sound reasonable?