Re: Linear RAID Failure
From: Neil Brown <hidden>
Date: 2004-05-04 02:15:04
On Wednesday April 28, mislam@uiuc.edu wrote:
Error reading block 175767553 (Attempt to read block from filesystem resulted in short read) while reading inode and block bitmaps. Ignore error? yes
...
What should I do at this point? I have the data backed up from yesterday. Should I replace the hdk and hdl? Can I just do a remove from the linear raid and add the new disks? Or I need to recreate the array.
It certainly appears that hdk and hdl are bad. I suggest replacing them. You cannot just remove drives and add others. That only works for arrays that have redundancy, such as raid1, raid5, or raid6. Linear is just like a single driver, only bigger. If it fails you have to restore from backups. NeilBrown