Re: RAID5 temperorary loss two disk
From: Daniel Pittman <hidden>
Date: 2004-04-29 02:46:08
On Wed, 28 Apr 2004, Don Jessup wrote:
I have RAID5 volume that has two disk that have been marked as failed. I believe this happen do to loss of communication with the disk. NOT because of a total disk failure. I assume if I can get the superblocks back into a good state I can reassemble the RAID5 and try to read what data I can off the volume. Does anyone know how to force RAID5 superblocks into a state so I can do reads from the volume? I really need help on this. By the way the kernel version is 2.4.22.
mdadm has a --force option to the assemble command which I have used to
recover from a similar situation. Don't forget to fsck the volume
afterwards, though, since it will have bad data on it.
Daniel
--
The Believer had better face himself and ask squarely: Do I literally
believe "God" has a penis? If the answer is no, then it seems only
logical to drop the ridiculous practice of referring to "God" as "he."
-- Robert Anton Wilson