Thread (7 messages) 7 messages, 4 authors, 2002-11-12
  • RAID-6 · "H. Peter Anvin" <hpa@zytor.com> · 2002-11-11
  • Re: RAID-6 · Derek Vadala <hidden> · 2002-11-11
  • Re: RAID-6 · Mr. James W. Laferriere <hidden> · 2002-11-11
  • Re: RAID-6 · "H. Peter Anvin" <hpa@zytor.com> · 2002-11-11
  • Re: RAID-6 · Jakob Oestergaard <hidden> · 2002-11-12
  • Re: RAID-6 · "H. Peter Anvin" <hpa@zytor.com> · 2002-11-12
  • Re: RAID-6 · "H. Peter Anvin" <hpa@zytor.com> · 2002-11-12

Re: RAID-6

From: "H. Peter Anvin" <hpa@zytor.com>
Date: 2002-11-11 23:05:21

Mr. James W. Laferriere wrote:
	Hello Peter ,

On 11 Nov 2002, H. Peter Anvin wrote:
quoted
Hi all,
I'm playing around with RAID-6 algorithms lately.  With RAID-6 I mean
a setup which needs N+2 disks for N disks worth of storage and can
handle any two disks failing -- this seems to be the contemporary
definition of RAID-6 (the originally proposed "two-dimensional parity"
which required N+2*sqrt(N) drives never took off for obvious reasons.)
	Was there a discussion of the 'two-dimensional parity' on the
	list ?  I don't remember any (of course) .  But what other than
	98+2+10 ,  What was the main difficulty ?  I don't (personally)
	see any difficulty (other than managability/power/space) to the
	ammount of disks required .  Tia ,  JimL
No discussion of two-dimensional parity, but that was the originally
proposed RAID-6.  Noone ever productized a solution like that to the
best of my knowledge.  I don't know what you mean with "98+2+10", but
the basic problem is that with 2D parity, for N data drives you need
2*sqrt(N) redundancy drives, which for any moderate-sized RAID is a lot
(with 9 data drives you need 6 redundancy drives, so you have 67%
overhead.)  You also have the same kind of performance problems as
RAID-4 does, because the "rotating parity" trick of RAID-5 does not work
in two dimensions.  And for all of this, you're not *guaranteed* more
than dual failure recovery (although you might, probabilistically, luck
out and have more than that.)

P+Q redundancy, the current meaning of RAID-6, instead uses two
orthogonal redundancy functions so you only need two redundancy drives
regardless of how much data you have, and you can apply the RAID-5 trick
of rotating the parity around.  So from your 15 drives in the example
above, you get 13 drives worth of data instead of 9.

	-hpa