[PATCH v2 12/16] power: supply: ab8500: Make recharge capacity a constant

From: Linus Walleij <hidden>
Date: 2021-11-20 15:56:09
Subsystem: ab8500 battery and charger drivers, power supply class/subsystem and drivers, the rest · Maintainers: Linus Walleij, Sebastian Reichel, Linus Torvalds

The recharge capacity is the hysteresis level for a charger to
restart when a battery does not support maintenance charging.

All products using the AB8500 have batteries supporting
maintenace charging and all code has always set this to 95%.

Turn it into a constant.

Signed-off-by: Linus Walleij <redacted>
---
ChangeLog v1->v2:
- Rebase on the other patches
---
 drivers/power/supply/ab8500-bm.h       |  4 ----
 drivers/power/supply/ab8500_bmdata.c   |  1 -
 drivers/power/supply/ab8500_chargalg.c | 10 ++++++++--
 3 files changed, 8 insertions(+), 7 deletions(-)
diff --git a/drivers/power/supply/ab8500-bm.h b/drivers/power/supply/ab8500-bm.h
index 4bc932109f63..58e4cb901076 100644
--- a/drivers/power/supply/ab8500-bm.h
+++ b/drivers/power/supply/ab8500-bm.h
@@ -374,9 +374,6 @@ struct ab8500_maxim_parameters {
  * struct ab8500_battery_type - different batteries supported
  * @resis_high:			battery upper resistance limit
  * @resis_low:			battery lower resistance limit
- * @recharge_cap		battery capacity limit that will trigger a new
- *				full charging cycle in the case where maintenan-
- *				-ce charging has been disabled
  * @normal_cur_lvl:		charger current in normal state in mA
  * @normal_vol_lvl:		charger voltage in normal state in mV
  * @maint_a_cur_lvl:		charger current in maintenance A state in mA
@@ -397,7 +394,6 @@ struct ab8500_maxim_parameters {
 struct ab8500_battery_type {
 	int resis_high;
 	int resis_low;
-	int recharge_cap;
 	int normal_cur_lvl;
 	int normal_vol_lvl;
 	int maint_a_cur_lvl;
diff --git a/drivers/power/supply/ab8500_bmdata.c b/drivers/power/supply/ab8500_bmdata.c
index cd1fc288314e..78182a396de7 100644
--- a/drivers/power/supply/ab8500_bmdata.c
+++ b/drivers/power/supply/ab8500_bmdata.c
@@ -83,7 +83,6 @@ static const struct batres_vs_temp temp_to_batres_tbl_thermistor[] = {
 static struct ab8500_battery_type bat_type_thermistor_unknown = {
 	.resis_high = 0,
 	.resis_low = 0,
-	.recharge_cap = 95,
 	.normal_cur_lvl = 400,
 	.normal_vol_lvl = 4100,
 	.maint_a_cur_lvl = 400,
diff --git a/drivers/power/supply/ab8500_chargalg.c b/drivers/power/supply/ab8500_chargalg.c
index 49e7167d0362..90974a8887cd 100644
--- a/drivers/power/supply/ab8500_chargalg.c
+++ b/drivers/power/supply/ab8500_chargalg.c
@@ -49,6 +49,13 @@
 #define CHARGALG_CURR_STEP_LOW		0
 #define CHARGALG_CURR_STEP_HIGH	100
 
+/*
+ * This is the battery capacity limit that will trigger a new
+ * full charging cycle in the case where maintenance charging
+ * has been disabled
+ */
+#define AB8500_RECHARGE_CAP		95
+
 enum ab8500_chargers {
 	NO_CHG,
 	AC_CHG,
@@ -1544,8 +1551,7 @@ static void ab8500_chargalg_algorithm(struct ab8500_chargalg *di)
 		fallthrough;
 
 	case STATE_WAIT_FOR_RECHARGE:
-		if (di->batt_data.percent <=
-		    di->bm->bat_type->recharge_cap)
+		if (di->batt_data.percent <= AB8500_RECHARGE_CAP)
 			ab8500_chargalg_state_to(di, STATE_NORMAL_INIT);
 		break;
 
-- 
2.31.1