Re: [PATCH v1 1/1] thermal: imx: implement runtime PM support

From: Oleksij Rempel <o.rempel@pengutronix.de>
Date: 2021-10-19 12:59:38
Also in: linux-arm-kernel, lkml

On Tue, Oct 19, 2021 at 01:55:32PM +0200, Daniel Lezcano wrote:
On 19/10/2021 13:51, Oleksij Rempel wrote:
quoted
Hi Daniel,

On Tue, Oct 19, 2021 at 01:04:46PM +0200, Daniel Lezcano wrote:
quoted
On 24/09/2021 13:50, Oleksij Rempel wrote:
quoted
Starting with commit d92ed2c9d3ff ("thermal: imx: Use driver's local
data to decide whether to run a measurement") this driver stared using
irq_enabled flag to make decision to power on/off the thermal core. This
triggered a regression, where after reaching critical temperature, alarm
IRQ handler set irq_enabled to false,  disabled thermal core and was not
able read temperature and disable cooling sequence.

In case the cooling device is "CPU/GPU freq", the system will run with
reduce performance until next reboot.

To solve this issue, we need to move all parts implementing hand made
runtime power management and let it handle actual runtime PM framework.

Fixes: d92ed2c9d3ff ("thermal: imx: Use driver's local data to decide whether to run a measurement")
Signed-off-by: Oleksij Rempel <o.rempel@pengutronix.de>
Thanks for this fix.

Petr or Oleksij,

could you confirm it is tested and working without CONFIG_PM ?
Petr was right, no it is not working without PM.
Ok, thanks.

I suppose the fix is related to the initialization of the sensor which
should be enabled with/out pm_runtime, right ?
No, i did sanity check on pm_runtime_put() within the probe. Without PM
it will properly return ENOSYS, so I aborted the probe. Looks like I
should ignore return value on this function like every driver is doing
it.

-- 
<http://www.linaro.org/> Linaro.org │ Open source software for ARM SoCs

Follow Linaro:  <http://www.facebook.com/pages/Linaro> Facebook |
<http://twitter.com/#!/linaroorg> Twitter |
<http://www.linaro.org/linaro-blog/> Blog
-- 
Pengutronix e.K.                           |                             |
Steuerwalder Str. 21                       | http://www.pengutronix.de/  |
31137 Hildesheim, Germany                  | Phone: +49-5121-206917-0    |
Amtsgericht Hildesheim, HRA 2686           | Fax:   +49-5121-206917-5555 |
Keyboard shortcuts
hback out one level
jnext message in thread
kprevious message in thread
ldrill in
Escclose help / fold thread tree
?toggle this help