@@ -380,11 +380,11 @@ static const struct tsens_ops ops_8976 = {
.get_temp = get_temp_tsens_valid,
};
-/* Valid for both MSM8956 and MSM8976. Sensor ID 3 is unused. */
+/* Valid for both MSM8956 and MSM8976. */
struct tsens_plat_data data_8976 = {
.num_sensors = 11,
.ops = &ops_8976,
- .hw_ids = (unsigned int[]){0, 1, 2, 4, 5, 6, 7, 8, 9, 10},
+ .hw_ids = (unsigned int[]){0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10},
.feat = &tsens_v1_feat,
.fields = tsens_v1_regfields,
};