Thread (22 messages) 22 messages, 5 authors, 2017-06-13

Re: [PATCH 5/5] power: supply: bq27xxx: Correct supply status with current draw

From: Pavel Machek <hidden>
Date: 2017-05-31 17:33:36
Also in: lkml

Hi!
quoted
quoted
The status reported directly by the battery controller is not always
reliable and should be corrected based on the current draw information.

This implements such a correction with a dedicated function, called
when retrieving the supply status.
quoted
quoted
@@ -1182,6 +1196,8 @@ static int bq27xxx_battery_status(struct
bq27xxx_device_info *di,
 		else
 			status = POWER_SUPPLY_STATUS_DISCHARGING;
 	} else {
+		curr = (int)((s16)curr) * 1000;
Umm.
As in "two casts in one expression -- too ugly to live".
quoted
quoted
@@ -1190,6 +1206,18 @@ static int bq27xxx_battery_status(struct
bq27xxx_device_info *di,
 			status = POWER_SUPPLY_STATUS_CHARGING;
 	}
 
+
+	if (curr == 0 && status != POWER_SUPPLY_STATUS_NOT_CHARGING)
+		status = POWER_SUPPLY_STATUS_FULL;
+
+	if (status == POWER_SUPPLY_STATUS_FULL) {
+		/* Drawing or providing current when full */
+		if (curr > 0)
+			status = POWER_SUPPLY_STATUS_CHARGING;
+		else if (curr < 0)
+			status = POWER_SUPPLY_STATUS_DISCHARGING;
+	}
Are you sure this works? On N900, we normally see small currents to/from
"full" battery.
In my case, this works perfectly and I am quite surprised of what you're
describing. Is it the case when the battery has a PSU connected?
"PSU"? This is cellphone. It has USB connection and charges from that.

It has been charging for long while now, and current_now fluctuates
between 20706 and -2856. USB has limitted current, so I guess "draw
current from battery if we need more than USB can provide" is quite common.

pavel@n900:~$ cat /sys/class/power_supply/bq27200-0/current_now
5355
pavel@n900:~$ cat /sys/class/power_supply/bq27200-0/current_now
5355
pavel@n900:~$ cat /sys/class/power_supply/bq27200-0/current_now
-4105
pavel@n900:~$ cat /sys/class/power_supply/bq27200-0/current_now
-4105
pavel@n900:~$ cat /sys/class/power_supply/bq27200-0/current_now
-7675
pavel@n900:~$ cat /sys/class/power_supply/bq27200-0/current_now
-5712
pavel@n900:~$ #screen on
pavel@n900:~$ cat /sys/class/power_supply/bq27200-0/current_now
4641
pavel@n900:~$ cat /sys/class/power_supply/bq27200-0/current_now
4641
pavel@n900:~$ cat /sys/class/power_supply/bq27200-0/current_now
37842
pavel@n900:~$ cat /sys/class/power_supply/bq27200-0/current_now
16600
pavel@n900:~$
I guess I would consider this a hardware issue (leak currents) and we could
definitely set some range (in device-tree) to distinguish between full + leak
currents and bad reporting from the fuel gauge. That would work well in my case
too.
I'd pass to userspace what the controller reports. Yes, I seldom see
"STATUS_FULL" but that may be a problem we need to track down.



       	  	 	     		 	      	    	    	 Pavel
-- 