Re: [bug report] NVMe/IB: reset_controller need more than 1min
From: Yi Zhang <hidden>
Date: 2021-12-17 07:03:43
Also in:
linux-rdma
On Fri, Dec 17, 2021 at 1:34 AM Haakon Bugge [off-list ref] wrote:
quoted
On 16 Dec 2021, at 17:32, Yi Zhang [off-list ref] wrote: On Thu, Dec 16, 2021 at 9:21 PM Max Gurtovoy [off-list ref] wrote:quoted
On 12/16/2021 4:18 AM, Yi Zhang wrote:quoted
On Wed, Dec 15, 2021 at 8:10 PM Max Gurtovoy [off-list ref] wrote:quoted
On 12/15/2021 3:15 AM, Yi Zhang wrote:quoted
On Tue, Dec 14, 2021 at 8:01 PM Max Gurtovoy [off-list ref] wrote:quoted
On 12/14/2021 12:39 PM, Sagi Grimberg wrote:quoted
quoted
quoted
quoted
Hi Sagi It is still reproducible with the change, here is the log: # time nvme reset /dev/nvme0 real 0m12.973s user 0m0.000s sys 0m0.006s # time nvme reset /dev/nvme0 real 1m15.606s user 0m0.000s sys 0m0.007sDoes it speed up if you use less queues? (i.e. connect with -i 4) ?Yes, with -i 4, it has stablee 1.3s # time nvme reset /dev/nvme0So it appears that destroying a qp takes a long time on IB for some reason...quoted
real 0m1.225s user 0m0.000s sys 0m0.007squoted
quoted
# dmesg | grep nvme [ 900.634877] nvme nvme0: resetting controller [ 909.026958] nvme nvme0: creating 40 I/O queues. [ 913.604297] nvme nvme0: mapped 40/0/0 default/read/poll queues. [ 917.600993] nvme nvme0: resetting controller [ 988.562230] nvme nvme0: I/O 2 QID 0 timeout [ 988.567607] nvme nvme0: Property Set error: 881, offset 0x14 [ 988.608181] nvme nvme0: creating 40 I/O queues. [ 993.203495] nvme nvme0: mapped 40/0/0 default/read/poll queues. BTW, this issue cannot be reproduced on my NVME/ROCE environment.Then I think that we need the rdma folks to help here...Max?It took me 12s to reset a controller with 63 IO queues with 5.16-rc3+. Can you try repro with latest versions please ? Or give the exact scenario ?Yeah, both target and client are using Mellanox Technologies MT27700 Family [ConnectX-4], could you try stress "nvme reset /dev/nvme0", the first time reset will take 12s, and it always can be reproduced at the second reset operation.I created a target with 1 namespace backed by null_blk and connected to it from the same server in loopback rdma connection using the ConnectX-4 adapter.Could you share your loop.json file so I can try it on my environment?{ "hosts": [], "ports": [ { "addr": { "adrfam": "ipv4", "traddr": "<ip>", "treq": "not specified", "trsvcid": "4420", "trtype": "rdma" }, "portid": 1, "referrals": [], "subsystems": [ "testsubsystem_0" ] } ], "subsystems": [ { "allowed_hosts": [], "attr": { "allow_any_host": "1", "cntlid_max": "65519", "cntlid_min": "1", "model": "Linux", "serial": "3d83c78b76623f1d", "version": "1.3" }, "namespaces": [ { "device": { "nguid": "5b722b05-e9b6-542d-ba80-62010b57775d", "path": "/dev/nullb0", "uuid": "26ffc8ce-73b4-321d-9685-7d7a9872c460" }, "enable": 1, "nsid": 1 } ], "nqn": "testsubsystem_0" } ] }Thanks, I reproduced it with your json file on one server with loopback rdma connection: # time nvme connect -t rdma -a 172.31.0.202 -s 4420 -n testsubsystem_0 real 0m4.557s user 0m0.000s sys 0m0.005s # time nvme reset /dev/nvme0 real 0m13.176s user 0m0.000s sys 0m0.007s # time nvme reset /dev/nvme0 real 1m16.577s user 0m0.002s sys 0m0.005s # time nvme disconnect -n testsubsystem_0What does: # rdma res show qp | grep -c ERR say, when it is slow?
Hi Haakon Here is the output during the reset operation: 38 33 28 24 19 14 9 4 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0 0 0
Thxs, Håkon
-- Best Regards, Yi Zhang