Date: 2019-06-24 18:35:24
Minwoo Im, Thanks for the explanation. Alex. -----Original Message----- From: Minwoo Im Sent: Sunday, June 23, 2019 2:57 PM To: Alex Lyakas Cc: Sagi Grimberg ; Keith Busch ; Minwoo Im ; linux-nvme ; Minwoo Im Subject: Re: [RFC] mismatch between chardev and blkdev node names On 19-06-23 20:54:25, Minwoo Im wrote:
On 19-06-23 11:13:54, Alex Lyakas wrote:quoted
Hello, if we look at the UDEV DEVPATH propertys of a particular nvme block device, for example: DEVPATH=/devices/virtual/nvme-fabrics/ctl/nvmeX/nvmeYnZ Would it be correct to say that "nvmeX" is the controller instance for this particular block device (or one of the instances)?Yes, for the above path, The corresponding blkdev of the nvmeX subsystem is nvmeYnZ. We just need to be aware if the MULTIPATH is enabled or
I mean if subsystem has multiple namespaces, then nvmeYnZ is one of them.
not. If so, the X will be a subsystem instance which can be checked by nvme list-subsys. If not, the X is the controller instance name. Thanks,