Re: [PATCH 2/3] thermal: Add Mediatek thermal controller support

From: Daniel Lezcano <hidden>
Date: 2015-08-20 22:29:27
Also in: linux-pm, lkml

On 08/21/2015 12:20 AM, Eduardo Valentin wrote:
On Thu, Aug 20, 2015 at 10:06:01AM +0200, Sascha Hauer wrote:
quoted
This adds support for the Mediatek thermal controller found on MT8173
and likely other SoCs.
The controller is a bit special. It does not have its own ADC, instead
it controls the on-SoC AUXADC via AHB bus accesses. For this reason
we need the physical address of the AUXADC. Also it controls a mux
using AHB bus accesses, so we need the APMIXEDSYS physical address aswell.

Signed-off-by: Sascha Hauer <s.hauer@pengutronix.de>
---
[ ... ]
quoted
+	/*
+	 * These calibration values should finally be provided by the
+	 * firmware or fuses. For now use default values.
+	 */
+	mt->calib_slope = -123;
+	mt->calib_offset = 465124;
Would it make sense to use the coefficients device tree property to
describe the sensor slope and offset?
Trim the mail when possible please.


-- 