Re: v4l: how to get blanking clock count?
From: Sakari Ailus <sakari.ailus@iki.fi>
Date: 2012-01-15 08:44:35
Hi Scott, On Wed, Jan 04, 2012 at 05:59:45PM +0800, Scott Jiang wrote:
quoted
quoted
If I disable this interrupt, other errors like fifo underflow are ignored. Perhaps I can add a parameter in platform data to let user decide to register this interrupt or not.I think a more generic solution would be preferrable. If that causes ignoring real errors, that's of course bad. I wonder if there would be a way around that. Is there a publicly available datasheet for the bridge that I could take a look at?Yes, http://www.analog.com/en/processors-dsp/blackfin/adsp-bf548/processors/technical-documentation/index.html. There is a hardware reference manual for bf54x, bridge is eppi.
Yeah, indeed it's the first time I see hardware like this. So to support this properly, we truly need the new sensor control interface and an ability to make those blanking values unchangeable. -- Sakari Ailus e-mail: sakari.ailus@iki.fi jabber/XMPP/Gmail: sailus@retiisi.org.uk