Map the Arctis 9 raw battery value over 0x64 (empty) to 0x9a (full)
instead of 0x68 to 0x9d. These values match the HeadsetControl project
[1] and fit the calibration points from an independent reverse
engineering of the battery tray (about 25% at raw 112, 50% at raw 125)
[2].

I do not have this headset. The values come from those references and
were not measured directly.

[1] https://github.com/Sapd/HeadsetControl/blob/master/lib/devices/steelseries_arctis_9.hpp
[2] https://magnier.io/reverse-engineering-arctis-9-battery-tray/

Signed-off-by: Sriman Achanta <redacted>
---
 drivers/hid/hid-steelseries-arctis.c | 2 +-
 1 file changed, 1 insertion(+), 1 deletion(-)
diff --git a/drivers/hid/hid-steelseries-arctis.c b/drivers/hid/hid-steelseries-arctis.c
index ce5875c03e73..d1552bf6567b 100644
--- a/drivers/hid/hid-steelseries-arctis.c
+++ b/drivers/hid/hid-steelseries-arctis.c
@@ -141,7 +141,7 @@ static void steelseries_arctis_9_parse_status(struct steelseries_device *sd,
 	if (data[0] == 0xaa && data[1] == 0x01) {
 		sd->headset_connected = true;
 		sd->battery_charging = (data[4] == 0x01);
-		sd->battery_capacity = steelseries_map_capacity(data[3], 0x68, 0x9d);
+		sd->battery_capacity = steelseries_map_capacity(data[3], 0x64, 0x9a);
 	} else {
 		/* Device off: 0x55 (no status) or 0x03 (stale status). */
 		sd->headset_connected = false;
-- 
2.54.0