On Tue, 27 Oct 2020, Dmitry Torokhov wrote:
M
On Wed, Oct 07, 2020 at 03:05:13PM -0700, Kenneth Albanowski wrote:
quoted
I've tested this locally backported to a 4.19 variant; it does work,
and provides the expected additional CHANGE events while safely
limiting the rate.
This seems like a reasonable minimum improvement, just ensuring
information already being pushed by HID reports can be utilized.
I'm unsure about mapping Digitizers.InRange to power_supply 'present',
in the abstract. It seems there could be a device where
Digitizers.BatteryStrength is sent, despite Digitizers.InRange=0, and
the HID Usage Tables don't quite seem to rule this out (depending on
how battery status collection interacts with 'the region where
digitizing is possible', section 16.3.1.).
As-is, this is useful and sufficient to get more timely reports up to userspace.
Jiri, if there are no better ideas, maybe this one can be applied?
Agreed (I certainly don't have better one :) ). Applied, thanks.
--
Jiri Kosina