Re: [PATCH] HID: wacom: Recognize new MobileStudio Pro PID
From: Benjamin Tissoires <hidden>
Date: 2019-12-18 15:54:24
On Mon, Dec 16, 2019 at 7:19 PM Gerecke, Jason [off-list ref] wrote:
From: Jason Gerecke <redacted> A new PID is in use for repaired MobileStudio Pro devices. Add it to the list of devices that need special-casing in wacom_wac_pad_event. Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com> ---
Thanks, Applied to for-5.5/upstream-fixes Cheers, Benjamin
quoted hunk ↗ jump to hunk
drivers/hid/wacom_wac.c | 6 ++++-- 1 file changed, 4 insertions(+), 2 deletions(-)diff --git a/drivers/hid/wacom_wac.c b/drivers/hid/wacom_wac.c index ccb74529bc78..d99a9d407671 100644 --- a/drivers/hid/wacom_wac.c +++ b/drivers/hid/wacom_wac.c@@ -2096,14 +2096,16 @@ static void wacom_wac_pad_event(struct hid_device *hdev, struct hid_field *field (hdev->product == 0x34d || hdev->product == 0x34e || /* MobileStudio Pro */ hdev->product == 0x357 || hdev->product == 0x358 || /* Intuos Pro 2 */ hdev->product == 0x392 || /* Intuos Pro 2 */ - hdev->product == 0x398 || hdev->product == 0x399)) { /* MobileStudio Pro */ + hdev->product == 0x398 || hdev->product == 0x399 || /* MobileStudio Pro */ + hdev->product == 0x3AA)) { /* MobileStudio Pro */ value = (field->logical_maximum - value); if (hdev->product == 0x357 || hdev->product == 0x358 || hdev->product == 0x392) value = wacom_offset_rotation(input, usage, value, 3, 16); else if (hdev->product == 0x34d || hdev->product == 0x34e || - hdev->product == 0x398 || hdev->product == 0x399) + hdev->product == 0x398 || hdev->product == 0x399 || + hdev->product == 0x3AA) value = wacom_offset_rotation(input, usage, value, 1, 2); } else { --2.24.1