Re: [PATCH v2 1/2] Input: mms114 - use smbus functions whenever possible
From: Andi Shyti <hidden>
Date: 2019-10-21 17:18:59
quoted
quoted
On Sun, Oct 20, 2019 at 11:28:55PM +0300, Andi Shyti wrote:quoted
The exchange of data to and from the mms114 touchscreen never exceeds 256 bytes. In the worst case it goes up to 80 bytes in the interrupt handler while reading the events.i2c_smbus_read_i2c_block_data() is actually limited to I2C_SMBUS_BLOCK_MAX = 32.oh sorry, I don't know how I slipped on this. But this means that the i2c in the kernel is wrong (or outdated), smbus specifies 256 bytes of data[*]. I might have relied on the specification more than the code. I guess SMBUS needs some update.You are right. It seems like that part of the specification was changed with SMBus version 3.0 [1]: D.6 255 Bytes in Process Call: The maximum number of bytes allowed in the Block Write-Block Read Process Call (Section 6.5.8) was increased from 32 to 255. [1]: http://www.smbus.org/specs/SMBus_3_0_20141220.pdf
yes :) OK, then I would ask Dmitry to hold on this patch I will try to update the smbus properly. Thanks a lot for the review, Stephan! Andi