Thread (2 messages) 2 messages, 2 authors, 2015-11-24

Re: [PATCH v8 1/8] ARM: dt: Binding documentation for imx25 ADC/TSC

From: Markus Pargmann <hidden>
Date: 2015-11-24 10:44:51
Also in: linux-arm-kernel, linux-devicetree, linux-iio

Possibly related (same subject, not in this thread)

On Monday 23 November 2015 14:59:52 Lee Jones wrote:
On Mon, 16 Nov 2015, Markus Pargmann wrote:
quoted
This documentation describes the devicetree bindings for the
ADC/Touchscreen unit of the i.MX25 SoC.

Signed-off-by: Markus Pargmann <redacted>
Acked-by: Jonathan Cameron <redacted>
---

Notes:
    Changes in v6:
     - Removed adc-ref property and replaced it with refp and refn for positive and
       negative references. The properties are optional now as the default
       behaviour is a positive internal reference voltage and ADC GND as negative
       reference.

 .../devicetree/bindings/mfd/fsl-imx25-tsadc.txt    | 46 ++++++++++++++++++++++
 1 file changed, 46 insertions(+)
 create mode 100644 Documentation/devicetree/bindings/mfd/fsl-imx25-tsadc.txt
diff --git a/Documentation/devicetree/bindings/mfd/fsl-imx25-tsadc.txt b/Documentation/devicetree/bindings/mfd/fsl-imx25-tsadc.txt
new file mode 100644
index 000000000000..a857af0eb68c
--- /dev/null
+++ b/Documentation/devicetree/bindings/mfd/fsl-imx25-tsadc.txt
@@ -0,0 +1,46 @@
+Freescale mx25 ADC/TSC multifunction device
Prefer "MX25" and "MultiFunction Device (MFD)"
Fixed.
quoted
+This device combines two general purpose conversion queues one used for general
+ADC and the other used for touchscreens.
+
+Required properties:
+ - compatible: Should be "fsl,imx25-tsadc".
+ - reg: Memory range of the device.
Not exactly.  More like start location and size.
quoted
+ - interrupts: Interrupt for this device as described in
+   interrupts/interrupts.txt
No such file.  In any case, I'd prefer:

"(See: ../interrupt-controller/interrupts.txt)".
quoted
+ - clocks: An 'ipg' clock defined as described in clocks/clock.txt
Didn't you check any of what you've written?

"(See: ../clock/clock-bindings.txt)"
Seems I didn't check these, sorry.
quoted
+ - interrupt-controller: This device is an interrupt controller. It controls
+   the interrupts of both conversion queues.
+ - #interrupt-cells: Should be '<1>'.
+ - #address-cells: Should be '<1>'.
+ - #size-cells: Should be '<1>'.
+ - ranges
?

Also, don't think think that this looks better/easier to read?
Yes a bit, changed it.
quoted
+Required properties:
+ - compatible:		Should be "fsl,imx25-tsadc".
+ - reg:			Memory range of the device.
+ - interrupts:		Interrupt for this device as described in
+				interrupts/interrupts.txt
+ - clocks:			An 'ipg' clock defined as described in clocks/clock.txt
+ - interrupt-controller:	This device is an interrupt controller. It controls
+   				the interrupts of both conversion queues.
+ - #interrupt-cells:		Should be '<1>'.
+ - #address-cells:		Should be '<1>'.
+ - #size-cells:		Should be '<1>'.
[...]
quoted
+This device includes two conversion queues which can be added as subnodes.
+The first queue is for the touchscreen, the second for general purpose ADC.
+
+Example:
+	tscadc: tscadc@50030000 {
+		compatible = "fsl,imx25-tsadc";
+		reg = <0x50030000 0xc>;
+		interrupts = <46>;
+		clocks = <&clks 119>;
+		clock-names = "ipg";
I don't think this is required, if you only have a single clock.
I prefer this variation so that you immediately see what the clock is
for. The number is not terribly helpful.

Thanks,

Markus
quoted
+		interrupt-controller;
+		#interrupt-cells = <1>;
+		#address-cells = <1>;
+		#size-cells = <1>;
+		ranges;
+
+		tsc: tcq@50030400 {
+			compatible = "fsl,imx25-tcq";
+			reg = <0x50030400 0x60>;
+			...
+		};
+
+		adc: gcq@50030800 {
+			compatible = "fsl,imx25-gcq";
+			reg = <0x50030800 0x60>;
+			...
+		};
+	};
-- 
Pengutronix e.K.                           |                             |
Industrial Linux Solutions                 | http://www.pengutronix.de/  |
Peiner Str. 6-8, 31137 Hildesheim, Germany | Phone: +49-5121-206917-0    |
Amtsgericht Hildesheim, HRA 2686           | Fax:   +49-5121-206917-5555 |

Attachments

Keyboard shortcuts
hback out one level
jnext message in thread
kprevious message in thread
ldrill in
Escclose help / fold thread tree
?toggle this help