[PATCH v3 10/20] power_supply: charger-manager: Use power_supply_*() API for accessing function attrs
From: Krzysztof Kozlowski <hidden>
Date: 2015-01-30 14:54:12
Also in:
linux-acpi, linux-arm-kernel, linux-pm, linux-tegra, lkml, platform-driver-x86
Subsystem:
the rest · Maintainer:
Linus Torvalds
Replace direct calls to power supply function attributes with wrappers. Wrappers provide safe access in case of unregistering the power supply (e.g. by removing the driver). Replace: - get_property -> power_supply_get_property Signed-off-by: Krzysztof Kozlowski <redacted> Acked-by: Jonghwa Lee <redacted> Acked-by: Pavel Machek <redacted> Reviewed-by: Bartlomiej Zolnierkiewicz <redacted> Reviewed-by: Sebastian Reichel <sre@kernel.org> --- drivers/power/charger-manager.c | 37 ++++++++++++++++++++----------------- 1 file changed, 20 insertions(+), 17 deletions(-)
diff --git a/drivers/power/charger-manager.c b/drivers/power/charger-manager.c
index 1acb04629fa0..3a8ceacb1bee 100644
--- a/drivers/power/charger-manager.c
+++ b/drivers/power/charger-manager.c@@ -103,8 +103,8 @@ static bool is_batt_present(struct charger_manager *cm) if (!psy) break; - ret = psy->get_property(psy, - POWER_SUPPLY_PROP_PRESENT, &val); + ret = power_supply_get_property(psy, POWER_SUPPLY_PROP_PRESENT, + &val); if (ret == 0 && val.intval) present = true; break;
@@ -118,8 +118,8 @@ static bool is_batt_present(struct charger_manager *cm) continue; } - ret = psy->get_property(psy, POWER_SUPPLY_PROP_PRESENT, - &val); + ret = power_supply_get_property(psy, + POWER_SUPPLY_PROP_PRESENT, &val); if (ret == 0 && val.intval) { present = true; break;
@@ -155,7 +155,8 @@ static bool is_ext_pwr_online(struct charger_manager *cm) continue; } - ret = psy->get_property(psy, POWER_SUPPLY_PROP_ONLINE, &val); + ret = power_supply_get_property(psy, POWER_SUPPLY_PROP_ONLINE, + &val); if (ret == 0 && val.intval) { online = true; break;
@@ -183,7 +184,7 @@ static int get_batt_uV(struct charger_manager *cm, int *uV) if (!fuel_gauge) return -ENODEV; - ret = fuel_gauge->get_property(fuel_gauge, + ret = power_supply_get_property(fuel_gauge, POWER_SUPPLY_PROP_VOLTAGE_NOW, &val); if (ret) return ret;
@@ -223,7 +224,8 @@ static bool is_charging(struct charger_manager *cm) } /* 2. The charger should be online (ext-power) */ - ret = psy->get_property(psy, POWER_SUPPLY_PROP_ONLINE, &val); + ret = power_supply_get_property(psy, POWER_SUPPLY_PROP_ONLINE, + &val); if (ret) { dev_warn(cm->dev, "Cannot read ONLINE value from %s\n", cm->desc->psy_charger_stat[i]);
@@ -236,7 +238,8 @@ static bool is_charging(struct charger_manager *cm) * 3. The charger should not be FULL, DISCHARGING, * or NOT_CHARGING. */ - ret = psy->get_property(psy, POWER_SUPPLY_PROP_STATUS, &val); + ret = power_supply_get_property(psy, POWER_SUPPLY_PROP_STATUS, + &val); if (ret) { dev_warn(cm->dev, "Cannot read STATUS value from %s\n", cm->desc->psy_charger_stat[i]);
@@ -279,7 +282,7 @@ static bool is_full_charged(struct charger_manager *cm) val.intval = 0; /* Not full if capacity of fuel gauge isn't full */ - ret = fuel_gauge->get_property(fuel_gauge, + ret = power_supply_get_property(fuel_gauge, POWER_SUPPLY_PROP_CHARGE_FULL, &val); if (!ret && val.intval > desc->fullbatt_full_capacity) return true;
@@ -296,7 +299,7 @@ static bool is_full_charged(struct charger_manager *cm) if (desc->fullbatt_soc > 0) { val.intval = 0; - ret = fuel_gauge->get_property(fuel_gauge, + ret = power_supply_get_property(fuel_gauge, POWER_SUPPLY_PROP_CAPACITY, &val); if (!ret && val.intval >= desc->fullbatt_soc) return true;
@@ -580,7 +583,7 @@ static int cm_get_battery_temperature_by_psy(struct charger_manager *cm, if (!fuel_gauge) return -ENODEV; - return fuel_gauge->get_property(fuel_gauge, + return power_supply_get_property(fuel_gauge, POWER_SUPPLY_PROP_TEMP, (union power_supply_propval *)temp); }
@@ -901,7 +904,7 @@ static int charger_get_property(struct power_supply *psy, ret = -ENODEV; break; } - ret = fuel_gauge->get_property(fuel_gauge, + ret = power_supply_get_property(fuel_gauge, POWER_SUPPLY_PROP_CURRENT_NOW, val); break; case POWER_SUPPLY_PROP_TEMP:
@@ -924,7 +927,7 @@ static int charger_get_property(struct power_supply *psy, mdelay(2000); pr_err("End wait...\n"); - ret = fuel_gauge->get_property(fuel_gauge, + ret = power_supply_get_property(fuel_gauge, POWER_SUPPLY_PROP_CAPACITY, val); if (ret) break;
@@ -980,7 +983,7 @@ static int charger_get_property(struct power_supply *psy, break; } - ret = fuel_gauge->get_property(fuel_gauge, + ret = power_supply_get_property(fuel_gauge, POWER_SUPPLY_PROP_CHARGE_NOW, val); if (ret) {
@@ -1429,7 +1432,7 @@ static int cm_init_thermal_data(struct charger_manager *cm, int ret; /* Verify whether fuel gauge provides battery temperature */ - ret = fuel_gauge->get_property(fuel_gauge, + ret = power_supply_get_property(fuel_gauge, POWER_SUPPLY_PROP_TEMP, &val); if (!ret) {
@@ -1723,13 +1726,13 @@ static int charger_manager_probe(struct platform_device *pdev) cm->charger_psy.num_properties = psy_default.num_properties; /* Find which optional psy-properties are available */ - if (!fuel_gauge->get_property(fuel_gauge, + if (!power_supply_get_property(fuel_gauge, POWER_SUPPLY_PROP_CHARGE_NOW, &val)) { cm->charger_psy.properties[cm->charger_psy.num_properties] = POWER_SUPPLY_PROP_CHARGE_NOW; cm->charger_psy.num_properties++; } - if (!fuel_gauge->get_property(fuel_gauge, + if (!power_supply_get_property(fuel_gauge, POWER_SUPPLY_PROP_CURRENT_NOW, &val)) { cm->charger_psy.properties[cm->charger_psy.num_properties] =
--
1.9.1