Re: [PATCH] psmouse: Expose drift duration for IBM trackpoints

From
Dmitry Torokhov <dmitry.torokhov@gmail.com>
Date
2014-12-17 23:32:03
Reply to
haarp, 2014-12-17
On Wed, Dec 17, 2014 at 06:09:47PM +0100, haarp wrote:
Hello,

IBM Trackpoints have a feature to compensate for drift by
recalibrating themselves periodically. If for 0.5 seconds
there is no change in position, it uses this as the new zero.

This happens often when the trackpoint is in fact being used.
This is frustrating.

Raising the time solves the problem.
IBM's Trackpoint Engineering Specifications offer a
configuration register for this (rstdft1). It just needs to
be exposed by the driver, as others already are.

Cheers!
-Mike


IBM Trackpoints have a feature to compensate for drift by recalibrating
themselves periodically. By default, if for 0.5 seconds there is no change in
position, it's used as the new zero. This duration is too low. Often, the
calibration happens when the trackpoint is in fact being used.

IBM's Trackpoint Engineering Specifications show a configuration register that
allows changing this duration, rstdft1.

Expose it via sysfs among the other settings.

Signed-off-by: Mike Murdoch <redacted>
Applied, thank you.

-- 
Dmitry