On 05/29/2013 06:09 PM, Sebastian Andrzej Siewior wrote:
Usually we get all the values we wanted but it is possible, that te ADC
unit is busy performing the conversation for the HW events. In that case
-EBUSY is returned and the user may re-call the function.
Signed-off-by: Sebastian Andrzej Siewior <redacted>
Acked-by: Jonathan Cameron <redacted>
quoted hunk
---
drivers/iio/adc/ti_am335x_adc.c | 7 ++++++-
1 file changed, 6 insertions(+), 1 deletion(-)
diff --git a/drivers/iio/adc/ti_am335x_adc.c b/drivers/iio/adc/ti_am335x_adc.c
index df2de4c..6a00874 100644
--- a/drivers/iio/adc/ti_am335x_adc.c
+++ b/drivers/iio/adc/ti_am335x_adc.c
@@ -161,6 +161,7 @@ static int tiadc_read_raw(struct iio_dev *indio_dev,
int i;
unsigned int fifo1count, read;
u32 step = UINT_MAX;
+ bool found = false;
/*
* When the sub-system is first enabled,
@@ -185,10 +186,14 @@ static int tiadc_read_raw(struct iio_dev *indio_dev,
fifo1count = tiadc_readl(adc_dev, REG_FIFO1CNT);
for (i = 0; i < fifo1count; i++) {
read = tiadc_readl(adc_dev, REG_FIFO1);
- if (read >> 16 == step)
+ if (read >> 16 == step) {
*val = read & 0xfff;
+ found = true;
+ }
}
tiadc_writel(adc_dev, REG_SE, STPENB_STEPENB);
+ if (found == false)
+ return -EBUSY;
return IIO_VAL_INT;
}