Thread (8 messages) 8 messages, 2 authors, 2013-01-07

Re: [PATCH v2 0/1] Input: xpad - Implement wireless controller LED setting and fix connect time LED setting

From: Dmitry Torokhov <dmitry.torokhov@gmail.com>
Date: 2012-11-30 22:30:33
Also in: lkml

Hi Chris,

On Friday, November 30, 2012 01:54:06 PM Chris Moeller wrote:
I've submitted versions of this with prior patch sets, and this part
was never accepted, possibly because it depended on other patches to
work, or possibly because it wasn't so cleanly organized. This time,
I've split the LED setting command off into its own static function,
then call that on controller connect and optionally on LED setting
commands. The static function does not include any locking, because
locking inside the function which receives the incoming packets
deadlocks the driver, and does not appear to be necessary anyway.

It also removes all traces of the original bulk out function which was
designed for the purpose of setting the LED status on connect, as I
found that it actually does not work at all. It appears to try to send
the data, but nothing actually happens to the controller LEDs.
Attached is a reply I sent to on 7/4/11 to which you unfortunately never
responded. The issue is that of force feedback (rumble) and LED share the
same URB then access to that URB should be arbitrated. The attached
message contains a patch that attempts to implement that arbitration,
could you please try it out and see what changes are needed to make it
work?

Thanks.

-- 
Dmitry