Thread (2 messages) flat view 2 messages, 2 authors, 2012-05-14

Re: [PATCH] input: wacom: Use touch size for ABS_MT_TOUCH_MAJOR

From: Jeffrey Brown <hidden>
Date: 2012-05-11 05:38:43

Resending to list.

On Thu, May 10, 2012 at 10:32 PM, Jeffrey Brown [off-list ref] wrote:
I have tackled this problem in Android and it's a real nuisance.  As far as
I can tell, the vast majority of drivers don't use ABS_MT_TOUCH_MAJOR /
MINOR or ABT_MT_WIDTH_MAJOR / MINOR correctly.

The drivers should be applying a transformation to the hardware reported
'width' or 'area' measurements so that they can be reported up to user space
in terms of surface units.

There are two common transformations that may need to be applied.

1. Width values typically need linear scaling sometimes with a bias
constant.  eg. out = width * scale + bias.  The scale adapts linear width
measurements to surface units.  The bias is typically zero but some devices
have a measurement floor.

2. Area values typically need inverse quadratic scaling.  Taking the
assumption that the contact is circular, obtain a nominal width (diameter)
using the square root.  Thus we have the relation: out = sqrt(area) * scale
+ bias.

It is easy to determine which of the two schemes to apply by observing the
relation between reported width or area (in unknown device specific units,
possibly sensor cell sizes) versus physical size (in millimeters).  When
plotted, look for the linear or quadratic relation and choose accordingly.

(I have yet to find a touch controller that uses the same units to report
size as it uses for position.)

I often use coins as benchmark test objects of known size.  Dimes, nickels,
quarters, dollars...  (I wish I had some standard probes of various sizes.).
It is a good idea to get a range of objects of different sizes, particularly
in the 6-16mm range.

Special considerations:

1. Some devices do not report the individual size of each contact
correctly.  They may report a value that is a sum of the total area
covered.  A simple expedient is to divide the raw reported width or area by
the number of contacts for these devices.

2. Size measurement is by necessity an approximation.  Laying a finger flat
may distribute the contact area over an elongated region.  Often the device
does not report enough information to tell what is going on, so we often
must make the assumption that the contact is round.

3. The orientation vector reported by some devices can provide information
about the extent to which the contact is elongated in one direction or
another.  By combining this information with the overall area measurement we
can estimate appropriate values for MAJOR and MINOR that capture the
distribution.

4. The resolution field in the absinfo structure rarely seems to be
populated.  It would be very useful if it were so that applications could
get a sense of the relation between surface units and physical dimensions.
It is often more useful to know that a screen is 80mm wide or a touch is
18mm wide than it is to know how many pixels that represents.

I believe it would be very beneficial for the community to pull together and
fix drivers that currently report size incorrectly.  I would dearly love to
delete the code I have in Android that compensates for this problem using
input device configuration files in user space...

Jeff.

On May 9, 2012 12:14 PM, "Jason Gerecke" [off-list ref] wrote:
quoted
On Thu, Mar 15, 2012 at 8:22 PM, Chris Bagwell [off-list ref]
wrote:
quoted
On Thu, Mar 15, 2012 at 7:10 PM, Jason Gerecke [off-list ref]
wrote:
quoted
On Mon, Mar 12, 2012 at 3:41 PM, Chris Bagwell [off-list ref]
wrote:
quoted
On Fri, Mar 9, 2012 at 5:26 PM, Jason Gerecke [off-list ref]
wrote:
quoted
On Fri, Mar 9, 2012 at 2:30 PM, Chris Bagwell [off-list ref]
wrote:
quoted
On Wed, Mar 7, 2012 at 7:39 PM, Jason Gerecke [off-list ref]
wrote:
quoted
3rd-gen Bamboo devices report both "amplitude" and "size" data
in their touch packets. This patch changes the source for
ABS_MT_TOUCH_MAJOR to be the latter rather than the former.
---
 drivers/input/tablet/wacom_wac.c |    2 +-
 1 files changed, 1 insertions(+), 1 deletions(-)
diff --git a/drivers/input/tablet/wacom_wac.c
b/drivers/input/tablet/wacom_wac.c
index d0b0fc4..5daf11d 100644
--- a/drivers/input/tablet/wacom_wac.c
+++ b/drivers/input/tablet/wacom_wac.c
@@ -916,7 +916,7 @@ static void wacom_bpt3_touch_msg(struct
wacom_wac *wacom, unsigned char *data)
       if (touch) {
               int x = (data[2] << 4) | (data[4] >> 4);
               int y = (data[3] << 4) | (data[4] & 0x0f);
-               int w = data[6];
+               int w = data[5];

               input_report_abs(input, ABS_MT_POSITION_X, x);
               input_report_abs(input, ABS_MT_POSITION_Y, y);
--
1.7.9.1
I found time to test this patch and used "mtview" so I could get
some
visual feedback.

The lines because extremely thin with this change.  Part of reason I
quickly traced to we are setting range as 0-255 but I couldn't get
data[5] to go above a value of 18.  So I changed range to 0-16 and
it
works better but the lines still never gets very thick (this could
well be that mtview doesn't scale values and prefers 0-255.  I
didn't
look).
Looks like its a combination of two problems, one mine one
mtview's...

I did some reading, and the MT protocol docs specify that
ABS_MT_TOUCH_MAJOR are in terms of surface units. That means a value
of e.g. "20" should represent a touch that spans 20 units of X. The
touch sensor has a resolution of ~0.1mm, which would imply the touch
was only 2 mm wide... There's going to have to be a correction factor
to transform the value to something more appropriate.

As for mtview, it looks like it doesn't scale the major/minor axis
values based on the output size. At the very least it should scale
everything by roughly (output_max_x / sensor_max_x) so that a touch
taking up e.g. 10% of the tablet would take up 10% of the output.
I see now that I got lucky that I had a 0-255 value available and
didn't look into what I needed to report close enough.
quoted
quoted
Amplitude feels better to me using test apps but your in a better
position to say if we should really change this.  Please adjust
declared range though if you still think we should change this.

Chris
My main reasons for switching away from amplitude were that amplitude
is a very crude number (I think I can get three or four unique values
out of it), and that the tablet reports a size already. Worst case --
assuming a correction factor isn't sufficient to get data[5] working
as MAJOR -- we should at least send data[5] through PRESSURE (which
the MT docs state may be used instead of MAJOR/MINOR if the units are
arbitrary).
I've not found time to dig deeply to this (to compute real scale
value) but I'll offer this.  I compared behaviour of original data[6]
to this:

int w = (data[5] > 31) ? 255 : data[5] << 3;

and with mtview the size change is much more responsive and
consistent.  So I'm on board with changing to data[5] in some form.

Chris
I did a little more testing, and it looks like data[5] is proportional
to the area (not linear dimension) of the touch. Given the intended
semantics (and ignoring the huge blobs it produces in mtview),
int_sqrt(data[5] << 13) seems to work well. We'd probably have to
increase the maximum to 512 or 1024 though since I've been able to get
my palm to produce values of ~600...

Also, I don't yet know how these values scale between tablet sizes --
I imagine smaller tablets produce larger values (since their sensors
are denser), but haven't been able to get my hands on other hardware
yet.
You've already given it much more thought than I but I made the
following assumption a little bit related.  The sensors report X/Y
maximums of 4096 even though its a rectangle tablet. Thats why I made
sure resolution was reported proportionally.  Here is from Xorg log of
my medium size tablet:

 (--) Wacom Wireless Receiver Finger pad: Wacom Unknown USB tablet
maxX=4096 maxY=4096 maxZ=0 resX=18000 resY=29000

I suspect that same ratio also applies to width reporting as well.

I'm also guessing the value of size is really defining an ellipse with
fixed orientation.  But we can't really expose that to user as
WIDTH_MINOR because it will be incorrectly interrupted as a pressure
estimate.

But I suspect the above resolution calculation will help push the
scaling issue to user land and we can concentrate on reporting
something like the int_sqrt() values you've come up with.

Chris
Whoops. Looks like this fell off my radar.

So, if I were to adjust the uncorrected width by the aspect ratio to
get values for ABS_MT_TOUCH_MAJOR and ABS_MT_TOUCH_MINOR, would that
be correct? For example, should placing a quarter (diameter of
24.26mm) on my Intuos5 Medium (logical size: 4096 x 4096, physical
size: 223mm x 139mm) ideally report a contact with a MAJOR axis of 714
and MINOR axis of 445?
Quarters are great aren't they?  ;-)

Foil wrapped pencils and conductive metal rods work well too.  Low tech
solutions to high tech problems...
quoted
Jason

---
Day xee-nee-svsh duu-'ushtlh-ts'it;
nuu-wee-ya' duu-xan' 'vm-nvshtlh-ts'it.
Huu-chan xuu naa~-gha.
--
To unsubscribe from this list: send the line "unsubscribe linux-input" in
the body of a message to majordomo@vger.kernel.org
More majordomo info at  http://vger.kernel.org/majordomo-info.html
--
To unsubscribe from this list: send the line "unsubscribe linux-input" in
the body of a message to majordomo@vger.kernel.org
More majordomo info at  http://vger.kernel.org/majordomo-info.html
Keyboard shortcuts
hback out one level
jnext message in thread
kprevious message in thread
ldrill in
Escclose help / fold thread tree
?toggle this help