Re: [PATCH 4/8 v3] Input: synaptics - add image sensor support

Started by Dmitry Torokhov on Aug 17, 2011

open the first message on its own page

Message details and related content
On Thu, Aug 18, 2011 at 12:43:39AM +0800, Daniel Kurtz wrote:
On Thu, Aug 18, 2011 at 12:32 AM, Dmitry Torokhov <dmitry.torokhov@gmail.com
quoted
wrote:
quoted
On Wed, Aug 17, 2011 at 10:05:48PM +0800, Daniel Kurtz wrote:
quoted
On Mon, Aug 15, 2011 at 3:17 PM, Daniel Kurtz [off-list ref]
wrote:
quoted
quoted
Hi Henrik,

Thanks for the great feedback.

On Sat, Aug 13, 2011 at 5:09 AM, Henrik Rydberg [off-list ref]
wrote:
quoted
quoted
quoted
Hi Daniel,

looks good, some details below.

The ABS_MT_TOUCH_MAJOR is supposed to have zero intercept, to remain
compatible with user space handling of type A devices. Also, the
scale
quoted
quoted
quoted
should match the screen/pad size, such that the actual size of the
touch area can be deduced. In addition, based on the current sensor
technologies, ABS_MT_PRESSURE and ABS_MT_TOUCH_MAJOR are normally
mutually exclusive.

All in all, I would prefer to only report width via (the
single-finger
quoted
quoted
quoted
axis) ABS_TOOL_WIDTH, and only for compatibility reasons.

+
+static void synaptics_report_slot_agm(struct input_dev *dev, int
slot,
quoted
quoted
quoted
+                                   const struct synaptics_hw_state
*agm)
quoted
quoted
quoted
+{
+     input_mt_slot(dev, slot);
+     input_mt_report_slot_state(dev, MT_TOOL_FINGER, true);
+     input_report_abs(dev, ABS_MT_POSITION_X, agm->x);
+     input_report_abs(dev, ABS_MT_POSITION_Y, invert_y(agm->y));
+     input_report_abs(dev, ABS_MT_PRESSURE, agm->z);
+}
With ABS_MT_TOUCH_MAJOR dropped, sgm and agm seems to coincide...
....
quoted
Looks good otherwise.

Thanks,
Henrik
Ahh....  ok, this makes sense.  I missed this detail previously.
Basically:
 * Only report synaptics "w" as ABS_TOOL_WIDTH (for backwards
compatibility)
quoted
quoted
 * Report synaptics "z" as ABS_MT_TOUCH_MAJOR (assuming it is really
'width of finger in surface units'), and ABS_PRESSURE (for backwards
compatibility).
 * Don't use ABS_MT_PRESSURE.
 * This will simplify agm/sgm reporting by making them both reoprt
the same axes.
Hi Henrik,

I think I was wrong in my previous comment.

I agree we should drop reporting synaptics 'w' (4-15, arbitrary units)
in ABS_MT_TOUCH_MAJOR.
Instead, to support legacy, report 'w' in ABS_TOOL_WIDTH, and do not
report ABS_MT_TOUCH_MAJOR at all.

However, I believe we should still report synaptics 'z' (0-255, in
arbitrary units) as ABS_MT_PRESSURE.
This will, in turn, be used by input_mt_report_pointer_emulation() to
determine the correct ABS_PRESSURE to report for legacy userspace
uses.
Alternatively, you can use input_mt_set_value() to save Z value to be
used by input_mt_report_pointer_emulation() later, but not report it as
part of MT packet.
But I want userspace to get per-contact pressure, since it is used to
determine whether a given contact is a palm or finger, etc. The trackpad
does not report a useful per-contact "width" that can be used to generate
"TOUCH_MAJOR".
If the data reported is indeed pressure and it is indeed per-contact then yes,
it makes sense to report it as such. If the data reported is more like contact
size then report it as ABS_MT_TOUCH_MAJOR and use input_mt_set_value()
to "stash" it for legacy emulation.

-- 