Thread (15 messages) 15 messages, 2 authors, 2011-08-21

Re: [PATCH v2 1/6] input: misc: AD714x: The interrupt status registers should be read in row.

flat view

From: Dmitry Torokhov <dmitry.torokhov@gmail.com>
Date: 2011-05-19 08:00:49

On Wed, May 18, 2011 at 08:10:09PM +0100, Hennerich, Michael wrote:
Dmitry Torokhov wrote on 2011-05-18:
quoted
On Tue, May 17, 2011 at 12:01:27PM +0100, Hennerich, Michael wrote:
quoted
Hi Dmitry,

I noticed you added patches 2/6, 3/6, 4/6 and 5/6 to your next tree.
But how about these ones?

[PATCH v2 1/6] input: misc: AD714x: The interrupt status registers
should be read in row. [PATCH v2 6/6] input: misc: AD714x: Fix
endianness issues.
Hi Michael,

Still pondering these two, give me a couple of days please...

Thanks.
Hi Dmitry,

No Problem - let me know in case you need some further clarification.
Both patches are tested on several platforms and addresses real issues.

BTW - are you going to merge the adp5589 driver anytime soon?
Are there open issues you like to get addressed first?
Oh, thanks for reminding me of it, I queued it for .40.

Thanks.

-- 
Dmitry
Keyboard shortcuts
hback out one level
jnext message in thread
kprevious message in thread
ldrill in
Escclose help / fold thread tree
?toggle this help