Re: [PATCH 2/5] tsc2007: Add max_rt module parameter.
flat view
From: Dmitry Torokhov <dmitry.torokhov@gmail.com>
Date: 2011-05-17 05:58:41
On Tue, May 17, 2011 at 07:46:20AM +0200, Thierry Reding wrote:
* Dmitry Torokhov wrote:quoted
Hi Thierry, On Mon, May 16, 2011 at 10:33:00AM +0200, Thierry Reding wrote:quoted
Finger touch events or very quick stylus events on low-quality panels can cause the tsc2007 to read bogus values. Looking at oscilloscope snapshots, this seems to be caused by the touch event disappearing during the measurements. These bogus values result in misclicks, where the X and Y values deviate from the real position. Most of these misclicks can be filtered out by setting a low enough threshold for the maximum resistance (which is loosely the inverse of the pressure) allowed to consider a set of values valid. Since this behaviour is largely dependent on the type and quality of the panel, this commit introduces the max_rt parameter. The default value is kept at MAX_12BIT.I expect that the values, once selected, will not be changed for a given panel, so why don't we pass max_rt (and poll_delay and poll_interval) vi platform (board) data instead of being module parameters?I was using module parameters because it allows the parameters to be tuned at runtime. You are correct however in that they don't vary after being selected once. I can resend an updated patch series with those parameters added to the platform data if you prefer.
Yes, please.
By the way, Kwangwoo's email address no longer seems to be valid. Searching the kernel tree, there also seems to be kwangwoo.lee@gmail.com. Do you know if it is current?
No, I do not. -- Dmitry