Re: [patch] add module parameter to provide hardware-calibrated coordinate data for MicroTouch/3M touchscreens

Started by Jiri Kosina on Nov 25, 2008

open the first message on its own page

Message details and related content
On Mon, 24 Nov 2008, Dan Streetman wrote:
This patch adds a module parameter to report either the raw coordinate data or 
the hardware-calibrated coordinate data.  The default is set to the raw 
coordinates for backwards compatibilty.
Please don't forget to include input subsystem maitainer (Dmitry Torokhov) 
when sending patches to code residing in drivers/input. Added.
quoted hunk
@@ -294,6 +303,12 @@ static int mtouch_init(struct usbtouch_u
 			return ret;
 	}
 
+	// Default min/max xy are the raw values, override if using hw-calib
Please use style of comments that is in compliance with kernel coding 
style.

Otherwise I think that the patch is fine.

-- 
Jiri Kosina
SUSE Labs

--
To unsubscribe from this list: send the line "unsubscribe linux-usb" in
the body of a message to majordomo-u79uwXL29TY76Z2rM5mHXA@public.gmane.org
More majordomo info at  http://vger.kernel.org/majordomo-info.html