Thread (21 messages) 21 messages, 3 authors, 2014-10-15

[PATCH 8/8] iio: Add ABI documentation for input current readings

From: Adam Thomson <hidden>
Date: 2014-09-23 10:54:54
Also in: linux-api, linux-devicetree, linux-pm, lkml
Subsystem: iio subsystem and drivers, the rest · Maintainers: Jonathan Cameron, Linus Torvalds

Add information on in_current related readings.

Signed-off-by: Adam Thomson <redacted>
---
 Documentation/ABI/testing/sysfs-bus-iio | 17 +++++++++++++++++
 1 file changed, 17 insertions(+)
diff --git a/Documentation/ABI/testing/sysfs-bus-iio b/Documentation/ABI/testing/sysfs-bus-iio
index d760b02..37cd4d4 100644
--- a/Documentation/ABI/testing/sysfs-bus-iio
+++ b/Documentation/ABI/testing/sysfs-bus-iio
@@ -92,6 +92,18 @@ Description:
 		is required is a consistent labeling.  Units after application
 		of scale and offset are millivolts.

+What:		/sys/bus/iio/devices/iio:deviceX/in_currentY_raw
+What:		/sys/bus/iio/devices/iio:deviceX/in_currentY_supply_raw
+KernelVersion:	3.17
+Contact:	linux-iio@vger.kernel.org
+Description:
+		Raw (unscaled no bias removal etc.) current measurement from
+		channel Y. In special cases where the channel does not
+		correspond to externally available input one of the named
+		versions may be used. The number must always be specified and
+		unique to allow association with event codes. Units after
+		application of scale and offset are milliamps.
+
 What:		/sys/bus/iio/devices/iio:deviceX/in_capacitanceY_raw
 KernelVersion:	3.2
 Contact:	linux-iio@vger.kernel.org
@@ -227,6 +239,8 @@ What:		/sys/bus/iio/devices/iio:deviceX/in_accel_y_offset
 What:		/sys/bus/iio/devices/iio:deviceX/in_accel_z_offset
 What:		/sys/bus/iio/devices/iio:deviceX/in_voltageY_offset
 What:		/sys/bus/iio/devices/iio:deviceX/in_voltage_offset
+What:		/sys/bus/iio/devices/iio:deviceX/in_currentY_offset
+What:		/sys/bus/iio/devices/iio:deviceX/in_current_offset
 What:		/sys/bus/iio/devices/iio:deviceX/in_tempY_offset
 What:		/sys/bus/iio/devices/iio:deviceX/in_temp_offset
 What:		/sys/bus/iio/devices/iio:deviceX/in_pressureY_offset
@@ -249,8 +263,11 @@ Description:
 		to the _raw output.

 What:		/sys/bus/iio/devices/iio:deviceX/in_voltageY_scale
+What:		/sys/bus/iio/devices/iio:deviceX/in_currentY_scale
 What:		/sys/bus/iio/devices/iio:deviceX/in_voltageY_supply_scale
+What:		/sys/bus/iio/devices/iio:deviceX/in_currentY_supply_scale
 What:		/sys/bus/iio/devices/iio:deviceX/in_voltage_scale
+What:		/sys/bus/iio/devices/iio:deviceX/in_current_scale
 What:		/sys/bus/iio/devices/iio:deviceX/out_voltageY_scale
 What:		/sys/bus/iio/devices/iio:deviceX/out_altvoltageY_scale
 What:		/sys/bus/iio/devices/iio:deviceX/in_accel_scale
--
1.9.3
Keyboard shortcuts
hback out one level
jnext message in thread
kprevious message in thread
ldrill in
Escclose help / fold thread tree
?toggle this help