Thread (8 messages) 8 messages, 3 authors, 2012-09-15

Re: [PATCH v5] iio: adc: add new lp8788 adc driver

From: Lars-Peter Clausen <lars@metafoo.de>
Date: 2012-09-14 08:35:20
Also in: lkml

On 09/14/2012 02:33 AM, Kim, Milo wrote:
quoted
Hi,

One issue and a couple of nitpicks inline.
I really appreciate it.
Please see my questions below.
quoted
quoted
+	switch (mask) {
+	case IIO_CHAN_INFO_RAW:
+		ret = lp8788_get_adc_result(adc, id, val) ? -EIO :
IIO_VAL_INT;
quoted
+		break;
+	case IIO_CHAN_INFO_SCALE:
+		*val = (lp8788_scale[id] / 1000) * 1000;
+		*val2 = (lp8788_scale[id] % 1000) * 1000000;
This looks suspicious. E.g. if the entry in your table has the value
"1234"
you'd end up with a scale factor of 1000.234000000. Which looks wrong
for
two reasons, given that you return INT_PLUS_MICRO val2 should never
exceed 6
decimal digits and secondly val is multiplied by a factor of thousand.

Can you tell us in what unit the values in lp8788_scale are, that would
make
review easier.
The LP8788 has 13 ADC input selection.

ADC selection:
Battery voltage, general ADC1 and so on.

ADC result:
Result = MAX_VALUE * (raw + 0.5) / 4095  except ADC is the charger voltage
If the ADC input is the charger voltage,
Result = MAX_VALUE * (raw + 0.5) / (4095 * 0.48)

The raw value is from the registers.
It has the range between 0 to 4095. (12bits)

MAX_VALUE is constant for each selection.
For the battery voltage, there are three ADC inputs. 5.0/5.5/6.0V
Battery voltage for Max 5.0V = 5.0
Battery voltage for Max 5.5V = 5.5
Battery voltage for Max 6.0V = 6.0
Charger = 6.0
ADC1 = 2.5 

I'm afraid I still misunderstand how IIO ADC works.
Could you me some guide how to setup the scale in the driver?
The scale is a fixpoint value, which should be multiplied with the raw value
to get the result in the proper unit. The unit depends on the channel type,
e.g. for voltage it is mV and for temperature it is C. The number of decimal
places for the fixed point value depends on whether you return
INT_PLUS_MICRO it's 6, if you return INT_PLUS_NANO it is 9. The digits
before the decimal point are stored in "val" the digits after the decimal
point are stored in "val2".

E.g. if you have
*val = 1;
*val2 = 1256;
return INT_PLUS_MICRO;

your scale factor is 1.001256, if you'd return INT_PLUS_NANO you scale
factor would be 1.0000001256 instead.

In your case you could for example calculate the voltage scales as:

tmp = MAX_VALUE * 1000000 / 4095;
*val = tmp / 1000000;
*val2 = tmp % 1000000;

This assumes that MAX_VALUE is in millivolt.

E.g. if MAX_VALUE is 5.0V you should get a scale of 1.220703 (val = 1, val2
= 220703). Since your MAX_VALUE is fixed you can probably just pre-calculate
the result of MAX_VALUE * 1000000 / 4095 for each channel, similar like you
already did with your lp8788_scale table.

- Lars


Keyboard shortcuts
hback out one level
jnext message in thread
kprevious message in thread
ldrill in
Escclose help / fold thread tree
?toggle this help