On Mon 2018-03-26 11:52:09, Enric Balletbo i Serra wrote:
Before this patch the enable signal was set before the PWM signal and
vice-versa on power off. This sequence is wrong, at least, it is on
the different panels datasheets that I checked, so I inverted the sequence
to follow the specs.
For reference the following panels have the mentioned sequence:
- N133HSE-EA1 (Innolux)
- N116BGE (Innolux)
- N156BGE-L21 (Innolux)
- B101EAN0 (Auo)
- B101AW03 (Auo)
- LTN101NT05 (Samsung)
- CLAA101WA01A (Chunghwa)
Ok, but this changes behaviour for other panels, too. Are you sure you
are not breaking one of those?
Pavel
--